Power, Ground and Battery Cabling for Sites Equipped With Optional
Primary Surge Suppressor
– continued
DEC 2000
5-13
SC
t
300 BTS Hardware Installation, ATP and FRU Procedures
PRELIMINARY
Cables Needed
Table 5-2 provides the quantity and description of the cables needed.
Table 5-2: Cables Needed for Power, Earth Ground, and Battery Connections
Cable
Qty.
Part Number
Description
A
1–4
3087701C02
Ground cable, 8 -AWG, insulated copper wire. Requires one ring lug
connector.
S
1–4
3087854C02
AC input cable, 14 AWG, 5 m, is designed for 88–260 VAC power
input. Cable has Deutsch connector on both ends.
T
1
Customer
Supplied
AC Input power cable. 10–14 AWG, 90
_
C wire. Designed for
120–240 VAC.
U
1–4
3087854C04
DC input cable, 14 and 22 AWG, 5 m, is designed for 20 to 30 VDC
power input.
Y
1
Customer
Supplied
Master Ground Cable, 6 -AWG, insulated copper wire.
AC Input Cable Information
The information for the AC input cable(s) (Cable S) is given in
Figure 5-10 and Table 5-3.
Figure 5-10: AC Input Cable Connector Information
A
B
C
SOCKET POSITION ON CABLE
CONNECTOR SHOWN
Table 5-3: AC Input Cable Information
Connector
Wire Color
Description
A
Black
Line
B
Green
Ground
C
White
Neutral
5