© 1998-2012 by Magenta Research, LTD., All rights reserved.
Magenta Research, LTD, 128 Litchfield Road New Milford, CT 06776 USA
USA: (800) 805-0944
INT: (+1) 860-210-0546
www.magenta-research.com
Document # 5310269-01 Rev-01 (10/8/2012)
Page 1 of 4
MultiView
™ II AK600 Receiver:
Quick Start Guide
The
Magenta MultiView™ II AK600
receiver extends a video, audio, and serial signals over standard CAT5 cable
(also CAT5e and CAT6). There are user-configurable settings for video, audio, and serial options which can be
controlled from the front panel. For more details please refer to the complete
MultiView
™ II AK600 User Guide
,
available for download at
www.magenta-research.com
,
or scan the QR-code shown here to access the user guide directly:
Required Tools / Hardware / Materials:
Tools include a
ppropriate screwdriver(s) and mounting hardware
(optional, for example: rack-mount, wall or under-desk mounting). Required materials include appropriate cables for
your specific application.
Power-up Check:
After all signal and power cables are connected, then apply AC power. The
power-on
indicator should light. If
there is a local monitor attached, a video image should appear on the monitor. If there is no image on the display, recheck all cables
and ensure the display is turned on. Also check that the EQ is properly set
– this is most often the case when there is no display image.
Front Panel Controls:
(
Refer to Figure-2) There are four buttons (
CFG/MODE
,
SKEW/SEL, DOWN
and
UP)
, and several green
LED status indicators. These are used to control the operating modes of the receiver, and to display current status.
Status Indicators at power-up:
When the MVII-AK600 is first powered on, the status indicators will cycle through a test sequence,
then display the current EQ setting on LEDs 1-8
. This is the “normal” mode of operation:
POWER-ON
indicator is on.
CFG
indicator is off.
SKEW/RGB
indicator is off.
EQ/SQEW
indicators display current EQ settings (0 to 100%).
As previously noted, it is critical that the EQ setting be adjusted to compensate for the length of CAT5 cable leading back to the
transmitter. Skew compensation adjustment (if your MVII-AK600 is equipped with an AkuComp-II module) will also be important for best
image quality.
Figure 1
– MVII-AK600
Receiver Rear View
(Optional)
Depending on installation requirements
: At
any time during installation, the receiver may be securely
mounted using appropriate brackets and hardware.
PRECAUTIONS
: (1)
Do not apply AC power until instructed to
do so.
(2)
This equipment is not intended for, nor does it
support, distribution through an Ethernet network. Do not
connect these devices to any sort of networking or
telecommunications equipment!
(3)
Use only Magenta
Research L
TD approved MultiView™ II power adapters. Failure
to do so may damage this device and will void the warranty.
Figure 2
– MVII-AK600
Receiver Front View
Connect the CAT5 cable
via the
LINK INPUT
port.
(
Optional
) Connect the
output CAT5 cable via the
LINK OUTPUT
port.
Connect the VGA OUT
(HD15 connector) to the
display device.
(Optional
) Make your serial and/or audio connections
via the DB9
IOIO
or
AUX I/O
connectors, as needed.
Connect the DC power cable
(+5VDC @ 3A. max) to the
POWER
port.
Power-on indicator
EQ/SKEW
range indicators
SKEW/SEL
indicator
CFG
indicator:
Off
= norm
On
= Config mode-1
Flashing
= Config mode-2