EQ Adjustment:

 When the MVII-AK600 is operating in normal mode (CFG indicator is off), it is possible to quickly adjust the EQ. The 

EQ/SKEW

 indicators 1-8 will change accordingly to show 0 to 100% of the adjustment range. 

 

(starting in normal-mode) 

 

Press and hold the 

UP

 or 

DOWN

 button until the 

SKEW/RGB

 indicator turns on (VIOLET). Release the 

UP

 or 

DOWN

 button. 

 

Press the 

UP

 or 

DOWN

 buttons repeatedly to adjust the EQ setting, either one step at a time or hold for auto-repeat.  

 

To exit EQ-ADJUST mode, leave the buttons untouched for 10 seconds, or press the 

CFG

 button once. 

 

Note:

 

For best results, use the Magenta EQ/Skew “test pattern” image if possible. This is available from the Magenta website. 

 

Skew Adjustment:

 If the AkuComp-II skew module is installed, it is possible to quickly adjust the RGB values when the AK600 is 

operating in normal mode. The 

EQ/SKEW

 indicators 1-8 will show the current setting as 0-100% of the SKEW adjustment range. 

 

(starting in normal-mode)

 

 

RED skew adjust:

 Press and hold the 

SKEW/SEL

 button until the 

SKEW/RGB

 indicator turns on RED. Release the SKEW 

button. 

 

Press the 

UP

 or 

DOWN

 button repeatedly to adjust the RED skew value. 

 

GREEN skew adjust:

 Press and release the 

SKEW/SEL

 button. The 

SKEW/RGB

 indicator will turn GREEN. 

 

Press the 

UP

 or 

DOWN

 button repeatedly to adjust the GREEN value. 

 

BLUE skew adjust:

 Press and release the 

SKEW/SEL

 button. The 

SKEW/RGB

 indicator will turn BLUE. 

 

Press the 

UP

 or 

DOWN

 button to adjust the BLUE value. 

 

Pressing the 

SKEW/SEL

 button again will return you to step-2, allowing adjustment of the RED skew again. 

 

To exit SKEW-ADJUST mode, leave the buttons untouched for 10 seconds or press the 

CFG

 button. 

 

Note:

 For best result

s, use the Magenta EQ/Skew “test pattern” image if possible. This is available from the Magenta website. 

 

Changing Internal Settings:

 In configuration-mode (

CFG 

indicator = on or flashing), the 

CFG

 and 

SKEW/SEL

 buttons, plus the 

LED indicators (1-8) will allow you to change internal configuration settings. The changes are effective immediately and are saved in 
non-volatile memory. 

 

To enter configuration-mode:

 Press and hold the 

CFG

 button until the 

CFG

 indicator is 

ON. 

Once in this mode, LEDs 1-8 

will display the current settings as described in the tables below. You are now at configuration menu level-1. 

 

To exit configuration-mode:

 Leave the buttons untouched for 10 seconds or press the 

CFG

 button again. The 

CFG

 indicator 

will turn off (normal-mode).

 

Note:

 There are two configuration modes. CFG(on) = Mode-1, CFG(flashing) = Mode-2. 

Configuration (mode-1), Sync-mode Options

:

 The MVII-AK600 is factory-configured for auto-detecting the proper sync-mode 

(RepliSync-I normal/stretched). This mode is generally compatible with all existing MultiView transmitter and receiver products that 
support RepliSync (if they are also using their default settings). However, some video sources may require a custom sync-mode setting 
(especially at 1080p and 1920x1200 video resolutions). For these cases, one of the other sync-modes can be selected. Note that any 
connected MultiView device (transmitter or daisy-chained receiver) 

MAY

 also require a change to its sync-mode settings. Otherwise, 

you may not get a proper video display output at one or more receivers. 

(starting in normal-mode) 

 

Press and hold the 

CFG

 button until the 

CFG

 indictor is 

ON

. Release the 

CFG

 button. 

o

 

LEDs 1-8 will show the current value for all Mode-1 configuration settings as 

bright

 (same as 

ON

), 

dim

 (same as 

OFF

). 

 

Press and release the 

SKEW/SEL

 button once. 

 

LED indicators 1 and 2

 should be illuminated (either ON or DIM); all others (indicators 3-8) should be off.

 

 

Press the 

UP

 and 

DOWN

 buttons to step through the available sync-mode settings as shown below. 

 

To leave configuration-mode, leave the buttons untouched for 10 seconds or press the 

CFG

 button. 

 

LED1 

LED2 

Front Panel View 

Sync-mode Setting 

dim 

dim 

 
 
 
 

The MVII-AK600 will auto-detect the required RepliSync-

I mode (“normal” or 

“stretched”). This is the factory-default setting. 

dim 

ON 

  
 
 
 

Force RepliSync-II mode. This is compatible with MultiView II 

“RepliSync-II” mode 

only (when connected to a MultiView-II transmitter). 

ON 

dim 

 
 
 
 

Force fixed-sync mode. 

NOTE:

 The source MultiView transmitter must also be in 

fixed-sync mode. Note that H/V polarity settings must also be selected at each 
receiver. 

 

Note:

 There is no CFG1 parameter for LED3. 