EQ Adjustment:
When the MVII-AK600 is operating in normal mode (CFG indicator is off), it is possible to quickly adjust the EQ. The
EQ/SKEW
indicators 1-8 will change accordingly to show 0 to 100% of the adjustment range.
(starting in normal-mode)
Press and hold the
UP
or
DOWN
button until the
SKEW/RGB
indicator turns on (VIOLET). Release the
UP
or
DOWN
button.
Press the
UP
or
DOWN
buttons repeatedly to adjust the EQ setting, either one step at a time or hold for auto-repeat.
To exit EQ-ADJUST mode, leave the buttons untouched for 10 seconds, or press the
CFG
button once.
Note:
For best results, use the Magenta EQ/Skew “test pattern” image if possible. This is available from the Magenta website.
Skew Adjustment:
If the AkuComp-II skew module is installed, it is possible to quickly adjust the RGB values when the AK600 is
operating in normal mode. The
EQ/SKEW
indicators 1-8 will show the current setting as 0-100% of the SKEW adjustment range.
(starting in normal-mode)
RED skew adjust:
Press and hold the
SKEW/SEL
button until the
SKEW/RGB
indicator turns on RED. Release the SKEW
button.
Press the
UP
or
DOWN
button repeatedly to adjust the RED skew value.
GREEN skew adjust:
Press and release the
SKEW/SEL
button. The
SKEW/RGB
indicator will turn GREEN.
Press the
UP
or
DOWN
button repeatedly to adjust the GREEN value.
BLUE skew adjust:
Press and release the
SKEW/SEL
button. The
SKEW/RGB
indicator will turn BLUE.
Press the
UP
or
DOWN
button to adjust the BLUE value.
Pressing the
SKEW/SEL
button again will return you to step-2, allowing adjustment of the RED skew again.
To exit SKEW-ADJUST mode, leave the buttons untouched for 10 seconds or press the
CFG
button.
Note:
For best result
s, use the Magenta EQ/Skew “test pattern” image if possible. This is available from the Magenta website.
Changing Internal Settings:
In configuration-mode (
CFG
indicator = on or flashing), the
CFG
and
SKEW/SEL
buttons, plus the
LED indicators (1-8) will allow you to change internal configuration settings. The changes are effective immediately and are saved in
non-volatile memory.
To enter configuration-mode:
Press and hold the
CFG
button until the
CFG
indicator is
ON.
Once in this mode, LEDs 1-8
will display the current settings as described in the tables below. You are now at configuration menu level-1.
To exit configuration-mode:
Leave the buttons untouched for 10 seconds or press the
CFG
button again. The
CFG
indicator
will turn off (normal-mode).
Note:
There are two configuration modes. CFG(on) = Mode-1, CFG(flashing) = Mode-2.
Configuration (mode-1), Sync-mode Options
:
The MVII-AK600 is factory-configured for auto-detecting the proper sync-mode
(RepliSync-I normal/stretched). This mode is generally compatible with all existing MultiView transmitter and receiver products that
support RepliSync (if they are also using their default settings). However, some video sources may require a custom sync-mode setting
(especially at 1080p and 1920x1200 video resolutions). For these cases, one of the other sync-modes can be selected. Note that any
connected MultiView device (transmitter or daisy-chained receiver)
MAY
also require a change to its sync-mode settings. Otherwise,
you may not get a proper video display output at one or more receivers.
(starting in normal-mode)
Press and hold the
CFG
button until the
CFG
indictor is
ON
. Release the
CFG
button.
o
LEDs 1-8 will show the current value for all Mode-1 configuration settings as
bright
(same as
ON
),
dim
(same as
OFF
).
Press and release the
SKEW/SEL
button once.
LED indicators 1 and 2
should be illuminated (either ON or DIM); all others (indicators 3-8) should be off.
Press the
UP
and
DOWN
buttons to step through the available sync-mode settings as shown below.
To leave configuration-mode, leave the buttons untouched for 10 seconds or press the
CFG
button.
LED1
LED2
Front Panel View
Sync-mode Setting
dim
dim
The MVII-AK600 will auto-detect the required RepliSync-
I mode (“normal” or
“stretched”). This is the factory-default setting.
dim
ON
Force RepliSync-II mode. This is compatible with MultiView II
“RepliSync-II” mode
only (when connected to a MultiView-II transmitter).
ON
dim
Force fixed-sync mode.
NOTE:
The source MultiView transmitter must also be in
fixed-sync mode. Note that H/V polarity settings must also be selected at each
receiver.
Note:
There is no CFG1 parameter for LED3.