59
13 - Electrical Specifications
Operation of the Nautilarm outside of these specifications is not advised
and may cause damage and unexpected operation.
Parameter
Min
Max
Typ
Unit
Supply Voltage
8
15
12
V
WITH GPS:
Supply Current @ 12V
50
1000*
50
mA
WITHOUT GPS / GPS Off:
Supply Current @ 12V
17
1000*
17
mA
Battery Charging:
Supply Current @ 12V
230
1000*
500
mA
*These peak currents will only be drawn for a few mS during the
transmit uplink burst.