To enable the automatic generator operation, the programming mode must
be entered. Before any field reference points can be established the clock
must first be set. The clock set field is the last item in the programming
menu.
Clock Set:
The clock is a 24 hour clock. If the display reads 00:01, it is 12:01 a.m.
If the clock reads 13:00, it is 1:00 p.m. The hours and minutes will flash,
alternating every eight seconds. Use the Settings button to advance hours or
minutes.
The clock time and the generator start/stop programming will
be erased whenever the main battery disconnects are turned off.
Generator Start:
Selecting a state of charge (SOC) generator start point is affected by the
Fuel Gauge Cutout voltage setting. SOC start points are between 40-60 per-
cent, or the generator may be programmed to start at a specified voltage. The
manual start disables the automatic start.
Generator Stop:
Selecting a state of charge generator stop point is affected by the Fuel
Gauge Cutout voltage setting. SOC stop points are between 90-99 percent, or
the generator may be programmed to stop at the Absorb or Float point of
charge cycle. The manual off disables the automatic stop.
Begin Generator Quiet Time or End Generator Quiet Time:
The automatic generator start feature may be programmed to operate only
at certain times in the 24 hour clock period. Example: The user wants the
automatic generator to start operation at 10:00 a.m. and stop operation at
7:00 p.m.
End Generator Quiet Time:
This is the time which the automatic generator operation is to begin.
Using the example time above, the 24 hour clock would be set to 10.00 hrs.
Begin Generator Quiet Time:
This is the time which the automatic generator operation is set to stop.
Using the example time above as a reference, the 24 clock would be set to
19:00 hrs.
NOTE: If the generator started from the automatic start program
and has not reached the automatic stop set point when quiet time
begins, the generator will stop and “Gen Quiet Fault” will be dis-
played.
Electrical Systems - House
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
S I G N A T U R E
8 • 2 0 2
Summary of Contents for SIGNATURE 2001 series
Page 1: ......
Page 3: ...FOLD CUT ALONG DOTTED LINE FOLD...
Page 7: ......
Page 25: ......
Page 73: ...Driving Safety SIGNATURE SERIES 2 7 3 NOTES...
Page 75: ......
Page 99: ...Care Maintenance SIGNATURE 3 9 9 NOTES...
Page 101: ......
Page 127: ......
Page 157: ......
Page 177: ......
Page 187: ......
Page 223: ......
Page 259: ......