Heat Pump Operation:
Living room comfort control will operate the front roof air conditioner.
• Press the MODE button repeatedly until Heat Pump is dis-
played.
• Set desired fan speed by pressing the FAN button.
• Set desired heating temperature by pressing the UP or DOWN
buttons.
The bedroom comfort control will operate the rear roof air condition-
er and (if equipped) the center roof air conditioner.
• Press the MODE button repeatedly until Heat Pump is dis-
played.
• Pressing the Zone button to alternate between Zone One and
Zone Two. Zone One will control the bedroom roof air condi-
tioner and Zone Two will control the center roof air conditioner.
• Set desired fan speed by pressing the FAN button.
• Set desired heating temperature by pressing the UP or DOWN
buttons.
The Aqua-Hot heat system is specially designed for use in motorhomes. The
Aqua-Hot is an appliance combining a water heater with a furnace. The Aqua-
Hot will provide an almost endless supply of hot water and heat the interior of
the motorhome. A 50,000 BTU diesel fired burner and a 1,650 watt AC element
heats a 50/50 antifreeze solution to approximately 200º F. The antifreeze solu-
tion is pumped through heat exchangers located throughout the motorhome.
Four pumps are used to circulate the antifreeze solution. Three pumps supply
the solution to the interior heat exchangers. The fourth pump circulates the
antifreeze solution through the engine. Fresh water is heated when pumped
through a coil tube inside the aqua hot.
Chlorine bleach or other concentrated chlorine bearing chemicals can cause
failure to the Aqua-Hot’s Domestic Water Loop (copper tubing) if not properly
and thoroughly rinsed. The Aqua-Hot’s copper tubing is rated for use with fresh
water and winterization solutions only. Periodic flushing with common house-
hold chemicals, including bleach, has little or no effect on the heating system if
properly rinsed with the fresh water afterwards. Failure of copper tubing, espe-
cially soft or flexible copper, can result if materials other than water or winteri-
zation solutions are allowed to reside inside the piping for extended periods as
during storage or other periods of non-use. The most common cause for failure
is due to an extended exposure to chlorine, solutions containing chlorine (i.e.
bleach) or hydrochloric acid.
NOTE: The Aqua Hot must be turned ON before using any heat feature.
Appliances
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
S I G N A T U R E
4 • 1 1 9
AQUA HOT
MODE OFF
MODE
FAN
TEMP
UP
ON
OFF
DOWN
ZONE
ZONE 1
D
UO-
T
HERM
Heat Pump
Summary of Contents for SIGNATURE 2001 series
Page 1: ......
Page 3: ...FOLD CUT ALONG DOTTED LINE FOLD...
Page 7: ......
Page 25: ......
Page 73: ...Driving Safety SIGNATURE SERIES 2 7 3 NOTES...
Page 75: ......
Page 99: ...Care Maintenance SIGNATURE 3 9 9 NOTES...
Page 101: ......
Page 127: ......
Page 157: ......
Page 177: ......
Page 187: ......
Page 223: ......
Page 259: ......