branch circuit breakers in the main panel then supply AC power to the input
terminals of the inverter. The pass through relay inside the inverter trips sup-
plying AC power to the sub panel.
When using the inverter as the AC power source, the pass through relay is
normally closed. The AC power produced by the inverter supplies power to
the sub panel only.
WARNING: The 120 Volt AC panels contain high voltage which can
cause serious injury or death. Before beginning any work or testing pro-
cedures involving the electric panels, or any of the branch circuits, be
sure the motorhome is unplugged from shore power, the generator is not
running and the inverter is in the off position. Certain testing procedures
may require the AC power to be on. Only qualified personnel or person-
nel with electrical backgrounds should attempt any testing procedures.
Branch circuit breakers supply AC power to the different items or
“loads.” An electrical load is any item or device that will use current when
supplied with an electromotive force. Should a breaker “trip” from over cur-
rent use, or a short circuit condition, the load should be tested or disconnect-
ed to determine the reason the breaker tripped. If no cause is found, or not
readily apparent, reset the breaker by toggling the breaker to the OFF posi-
tion, then back to ON. Should the breaker trip again after the load is reap-
plied it may indicate a fault with that particular load. Do not continue to reset
breaker until the problem has been correctly diagnosed and corrected.
Electrical Systems - House
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
S I G N A T U R E
8 • 2 0 6
FRONT,
KITCHEN (GFI) 20 2
INVERTER (L2) 30 3
MICROWAVE 20 4
REFER 20 5
INVERTER (L1) 30 6
BATH, REAR (GFI) 20 7
LAMP TABLE
ARMREST, POWER 20 8
CURTAIN (OPT) (GFI)
1
Inverter Panel.
Summary of Contents for SIGNATURE 2001 series
Page 1: ......
Page 3: ...FOLD CUT ALONG DOTTED LINE FOLD...
Page 7: ......
Page 25: ......
Page 73: ...Driving Safety SIGNATURE SERIES 2 7 3 NOTES...
Page 75: ......
Page 99: ...Care Maintenance SIGNATURE 3 9 9 NOTES...
Page 101: ......
Page 127: ......
Page 157: ......
Page 177: ......
Page 187: ......
Page 223: ......
Page 259: ......