The remote is used to program or turn on or off the inverter. The RC7 GS
remote is a display only. All the programming information is retained in the
inverter. If the inverter exhibits unusual symptoms or behavior such as not
responding to commands or displaying erroneous error conditions, “re-
booting” the inverter may alleviate these symptoms.
To re-boot the inverter:
1.
Remove AC power from the inverter by disconnecting shore power
and/or shutting the generator off.
2.
Turn the main switch on the inverter to the
OFF
position.
3.
Switch house and chassis main battery disconnects to the
OFF
position.
4.
Wait 30 seconds, this allows time for capacitors to discharge.
5.
Switch house and chassis main battery disconnects to the
ON
position.
6.
Turn the main switch on the inverter to the
ON
position.
7.
Connect the shore power cord or start the generator.
The AC distribution panels
are located in the bedroom. The
main 120 Volt AC panel
receives power from the trans-
fer switch, which is supplied by
either shore power or the gener-
ator. The AC power is supplied
to the 50 amp main breaker
first, then the power is supplied
to the individual branch circuit
breakers. The panel label
describes the breaker layout and
the item, outlet or appliance to
which they pertain. The sub
panel receives AC power from
the inverter. The sub panel sup-
plies power to items which can
be operated by the inverter.
When operating from either
shore power or the generator,
the sub panel is automatically
supplied with AC power from
the pass through relay in the
inverter. When hooked to shore
power or operating from the
generator, the AC power goes to
the main AC panel first. The
Electrical Systems - House
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
S I G N A T U R E
8 • 2 0 5
Re-booting the
Inverter
DISTRIBUTION PANEL - HOUSE 110
AC Panel
FRONT A/C
REAR A/C 20 2
INVERTER (L2) 30 3
INVERTER (L1) 30 6
BLOCK HEATER 15 7
(GFI)
.
WASHER/DRYER 20 8A
WATER HEATER
AQUA HOT - OPT 20 8B
20 1
MAIN
50
4
5
Main Panel.
Summary of Contents for SIGNATURE 2001 series
Page 1: ......
Page 3: ...FOLD CUT ALONG DOTTED LINE FOLD...
Page 7: ......
Page 25: ......
Page 73: ...Driving Safety SIGNATURE SERIES 2 7 3 NOTES...
Page 75: ......
Page 99: ...Care Maintenance SIGNATURE 3 9 9 NOTES...
Page 101: ......
Page 127: ......
Page 157: ......
Page 177: ......
Page 187: ......
Page 223: ......
Page 259: ......