3.1
General Specifications
The following indicates the general specifications of the C Controller module.
* 1 This indicates the section of the power supply to which the equipment is assumed to be connected
between the public electrical power distribution network and the machinery within premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities. The
surge voltage withstand level for up to the rated voltage of 300V is 2500V.
* 2 This index indicates the degree to which conductive material is generated in terms of the
environment in which the equipment is used.
Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity caused by
condensing must be expected occasionally.
* 3 The storage ambient temperature is -20 to 75
if the system includes an AnS series module.
* 4 The operating ambient humidity and storage ambient humidity are 10 to 90%RH if the system
includes an AnS series module.
* 5 Do not use or store the C Controller system under pressure higher than the atmospheric pressure
at sea level.
Doing so can cause malfunction.
For use in a pressurized environment, please consult your local Mitsubishi representative.
* 6 When installing a commercial CompactFlash card into the C Controller module, please follow the
specifications of the C Controller module or the CompactFlash card, whichever is lower.
Table 3.1 General specifications
Item
Specifications
*6
Operating ambient temperature
0 to 55
Storage ambient temperature
-25 to 75
*
3
Operating ambient humidity
5 to 95%RH
*
4
, non-condensing
Storage ambient humidity
Vibration resistance
Compliant
with JIS B
3502 and IEC
61131-2
Frequency
Constant
acceleration
Half
amplitude
Sweep count
Under
intermittent
vibration
5 to 8.4Hz
3.5mm
10 times
each in X, Y
and Z
directions
8.4 to 150Hz
9.8m/s
2
Under
continuous
vibration
5 to 8.4Hz
1.75mm
8.4 to 150Hz
4.9m/s
2
Shock resistance
Compliant with JIS B 3502 and IEC 61131-2 (147m/s
2
, 3 times each in 3 directions X, Y, Z)
Operating atmosphere
No corrosive gases
Operating altitude
*
5
0 to 2000m
Installation location
Inside a control panel
Overvoltage category
*
1
II or less
Pollution degree
*
2
2 or less
Q12DCCPU-V
Q06CCPU-V
Q06CCPU-V-B
Q12DCCPU-V
Q06CCPU-V
Q06CCPU-V-B