TROUBLESHOOTING
16.4 Error Code List
16.4.1 Error codes and actions (for errors occurred in function execution)
16
- 68
9
DE
V
ICE DE
S
CRIPT
IO
N
10
MU
LT
IPL
E
CP
U SY
S
T
EM
O
V
ER
VI
E
W
11
MUL
T
IP
L
E
CP
U
S
Y
S
TE
M
CONFIGURA
TION
12
CONCE
PT
OF MU
LT
IPL
E
CP
U SY
S
T
EM
13
COMMUN
ICA
TIO
N
S
BE
TWE
E
N
CP
U
MODUL
ES
14
P
A
RAM
E
TE
RS
A
DDE
D
F
O
R MU
LT
IP
LE
C
P
U
S
YSTE
M
S
15
ST
A
R
TIN
G A
M
U
LT
IPLE
CP
U
SYS
TEM
16
TR
O
U
B
L
E
S
HOOTING
(2) Error codes returned by bus interface functions
The following provides the error descriptions and corrective actions corresponding to
individual error code returned in execution of bus interface functions.
For the common error codes returned by bus interface functions and MELSEC data
link functions, refer to the following.
* 1 In a single CPU system, reset the C Controller module.
In a multiple CPU system, reset CPU No. 1.
(To the next page)
Table 16.9 Error codes returned by bus interface functions
Return value
(HEX)
Error description
Corrective action
0
Completed normally
-201
(0xFF37)
Module identification error
The specified module identification is invalid.
Check the parameter.
Check the specified module.
Reboot the operating system.
*1
-202
(0xFF36)
Path error
The specified path is invalid.
Use the path pointer returned by "QBF_Open"
function.
-203
(0xFF35)
I/O No. error
The specified I/O No. is out of range.
Check the I/O No.
-204
(0xFF34)
I/O access size error
The specified I/O access size is out of range.
Check the I/O access size (I/O No. and read/
write size.)
-205
(0xFF33)
I/O No. error
The specified I/O No. is out of range.
Check the I/O No.
-206
(0xFF32)
Program execution type error
The specified program execution type is out of range.
Check the program execution type.
-208
(0xFF30)
Offset error
The specified offset is out of range.
AnS series module (buffer memory) was accessed.
Check the offset.
Check the I/O No.
-209
(0xFF2F)
Buffer memory size error
The specified offset plus size is out of range.
The address of data storage buffer pointer is 0.
Check the specified buffer memory size.
Check the offset plus size.
Check the data storage buffer pointer.
-210
(0xFF2E)
Read area size error
The read area size is smaller than the read size.
Check the read size and read area size.
-211
(0xFF2D)
Time setting error
Time setting is out of range.
Check the specified time.
-214
(0xFF2A)
Intelligent function module error
The intelligent function module is not mounted on the accessed slot.
Check the I/O No.
Check if the intelligent function module is
mounted properly.
-217
(0xFF27)
Driver not started
Driver has not been started.
Check if the driver has been started.
-218
(0xFF26)
Bus already opened
"QBF_Open" is executed twice.
Only one instance of "QBF_Open" can be
executed.
-219
(0xFF25)
Program name error
The specified program name is invalid
(The program name does not exist in the programmable controller
CPU or is not registered with a parameter).
Check the program name.
-220
(0xFF24)
WDT type error
The specified WDT type is out of range.
Check the WDT type.
-222
(0xFF22)
Bus master CPU reset error
Remote reset for the bus master CPU (CPU 1) has failed.
Allow "Remote reset" in the system settings for
the bus master CPU (CPU 1).
Change the status of the bus master CPU
(CPU 1) to STOP.
Check if the bus master CPU (CPU 1) is
programmable controller CPU.