![Mitsubishi Electric Q06CCPU-V User Manual Download Page 69](http://html.mh-extra.com/html/mitsubishi-electric/q06ccpu-v/q06ccpu-v_user-manual_1811831069.webp)
2
SYSTEM CONFIGURATION
2.2 Applicable Modules
2.2.1 Applicable I/O modules and intelligent function modules
2
- 17
1
O
V
ER
VI
E
W
2
SY
STEM
CONFIGURA
TION
3
SP
ECIFICA
T
IONS
4
FUNCTIONS
5
A
C
C
E
SS V
IA
N
E
TW
OR
K
MODUL
ES
6
P
R
EP
AR
A
T
OR
Y
PROCE
DUR
ES
A
ND
S
E
TTING
7
I/O NUM
BER
ASS
IGN
M
EN
T
8
M
E
M
O
RIE
S
A
ND
FI
L
E
S
2.2
Applicable Modules
This section introduces modules applicable to the C Controller module.
Precautions for using I/O modules and intelligent function modules, refer to the following.
2.2.1
Applicable I/O modules and intelligent function modules
The following table indicates the MELSEC-Q series I/O modules and intelligent function
modules that can be used with the C Controller module.
The MELSEC-AnS/Q2AS series I/O modules and special function modules are not
applicable.
(To the next page)
Table 2.4 Applicable modules
Module type
Model
Restrictions
AC input module
Q series modules are applicable.
For details, refer to the manual for respective
modules.
-
DC input module
DC/AC input module
High-speed input module
QX40H, QX70H, QX80H, QX90H
-
High-speed output module
QY41H
-
Contact output module
Q series modules are applicable.
For details, refer to the manual for respective
modules.
-
Triac output module
Transistor output module
DC input/transistor output
combined module
Interrupt module
QI60
-
QX40H, QX70H, QX80H, QX90H
(The module is available only when the
interrupt module is selected by setting the
function selector switch (SW2) to OFF.)
A/D converter module
Q64AD, Q68ADV, Q68ADI
Use the product of function version B or later.
Channel isolated A/D
converter module
Q64AD-GH, Q62AD-DGH, Q68AD-G,
Q66AD-DG
-
D/A converter module
Q62DAN, Q64DAN, Q68DAVN, Q68DAIN
-
Q62DA, Q64DA, Q68DAV, Q68DAI
Use the product of function version B or later.
Channel-isolated D/A
converter module
Q66DA-G, Q62DA-FG
-
Analog Input/Output Module
Q64AD2DA
-
Load Cell Input Module
Q61LD
-
Channel-isolated
temperature input module
Q64TD, Q68TD-G-H01, Q68TD-G-H02,
Q68RD3-G
-
Q64TDV-GH, Q64RD-G
Use the product of function version B or later.
Temperature input module
Q64RD
-
Temperature control module
Q64TCTTN, Q64TCTTBWN, Q64TCRTN,
Q64TCRTBWN
-
Q64TCTT, Q64TCTTBW, Q64TCRT,
Q64TCRTBW
Use the product of function version B or later.
Loop control module
Q62HLC
-
Summary of Contents for Q06CCPU-V
Page 2: ......
Page 612: ...APPX 48 Appendix 11 Functions Added by Version Upgrade APPENDICES Memo ...
Page 617: ......