APPENDICES
Appendix 9 Connection with GX Works2/GX Developer
Appendix 9.1 When accessing another CPU of a multiple CPU system
APPX
- 33
A
I
2) Set "PC side I/F" to "Ethernet board".
Set the detailed setting dialog box as follows.
• "Network No." and "Station No."do not need to be changed because they
are not used.
• For "Protocol", select either in "TCP" or "UDP".
3) Set "PLC side I/F" to "PLC module".
Set the detailed setting dialog box as follows.
• For "PLC mode", select "QCPU (Q mode)".
• The Ethernet port cannot be connected directly. Do not check the box.
• For "IP address", set the IP address of the connecting C Controller
module.
• C Controller modules cannot be searched by the
button.
4) Set "Other station" to "No other station".
5) For "Multiple CPU setting", set the CPU to be accessed.
Find CPU (Built-in Ethernet port) on network