96
8 DIAGNOSTIC AND MAINTENANCE FUNCTIONS
8.1 Self Diagnostics Function
Operation upon error occurring
The product operating status and LED status will differ depending on the type of error generated.
For error types, see the following page.
Operation upon error detection setting
Set operation settings upon error detection.
MELIPC operation upon error detection setting
Configure the operation of this product when a problem is detected by using "MELIPC operation upon error detection setting"
of "RAS Setting".
Window
[Basic Parameter]
[RAS Setting]
[MELIPC Operation Setting at Error Detected]
Displayed items
*1 If "Shutdown" is selected, the operation upon error detection is the same as when the SHUTDOWN switch is pressed. (
*2 If the Windows part continuously restarts, a window to select whether to start Windows in safe mode is displayed.
*3 If "Do not restart" is selected, the error code is recorded in the event history at error detection, the MAIN ERR LED is lit, and the WIN
RDY LED is off.
If "Restart" is selected, the Windows part is restarted at error detection, and an event stating it restarted automatically is saved in the
event history.
For details on the internal configuration of this product (Windows part and VxWorks part), refer to the following
manual.
MELIPC MI5000 Series User's Manual (Startup)
Precautions
■
Automatic restart at a Windows system error
If Windows automatic restart is enabled, and 'Restart' is selected for when the Windows part stops, this product may restart
repeatedly. If 'Restart' is selected, disable Windows automatic restart.
Windows Start
[Windows System Tools]
[Control Panel]
[System and Security]
[System]
[Advanced system
settings]
[Advanced]
[Startup and Recovery]
[Settings]
[System failure]
[Automatically restart]
■
If the MELIPC temperature error settings are "Shut down"
The product may not shut down if MI Configurator or programs that make file accesses are operating, or depending on the
status of Windows.
Item
Description
Setting range
MELIPC temperature error
Set the device operation upon detection of a Main module temperature
error.
If "Shutdown" is set, the VxWorks part and Windows part shut down when
an error is detected.
• Shut down
• Do not shut down
(Default: Shutdown)
Windows part stop
Set operation of the Windows part when a stop state is detected due to a
Windows blue screen including timeout detection from the Windows part
system watchdog timer or other issue.
• Do not restart
• Restart
(Default: Do not restart)
Summary of Contents for MELIPC MI5000 Series
Page 1: ...MELIPC MI5000 Series User s Manual Application MI5122 VW ...
Page 2: ......
Page 18: ...16 MEMO ...
Page 22: ...20 1 DIAGNOSTIC AND MAINTENANCE FUNCTIONS 1 1 Watchdog Timer WDT Function MEMO ...
Page 42: ...40 5 iQSS FUNCTION MEMO ...
Page 146: ...144 11 SECURITY FUNCTION 11 3 IP Filter Function MEMO ...
Page 148: ...146 12 MELSOFT PRODUCT AND GOT CONNECTION FUNCTION 12 1 Connection Method MEMO ...
Page 150: ...148 13 SYSTEM COUNT FUNCTION MEMO ...
Page 152: ...150 14 TIMER EVENT FUNCTION MEMO ...
Page 160: ...158 15 OS LINKING FUNCTIONS 15 3 Inter OS Event Notification Function MEMO ...
Page 162: ...160 16 SERIAL INTERFACE SWITCHING FUNCTION MEMO ...
Page 165: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 163 17 Operation related setting Window ...
Page 170: ...168 17 BASIC PARAMETERS 17 1 Basic Parameter List RAS setting Window ...
Page 174: ...172 17 BASIC PARAMETERS 17 1 Basic Parameter List External device connection settings Window ...
Page 313: ...APPX Appendix 10 List of VxWorks Components 311 A MEMO ...
Page 315: ...I 313 MEMO ...
Page 319: ......