APPX
Appendix 5 List of Special Relays
257
A
Appendix 5
List of Special Relays
The list of special relays contains the following information.
Do not change the special relay set by system with the operations such as program execution or device test.
Doing so may result in system down or disconnection of communication.
Item
Description
No.
Indicates the number of the special relay.
Name
Indicates the name of the special relay.
Content
Indicates the content of the special relay.
Details
Indicates the details of the special relay.
Set by
Indicates the timing to set each device by system and/or user.
■
Set by
• S: Set by system.
■
When to set
• Status change: Set only when the status is changed (by a special relay).
• Error occurrence: Set when an error occurs.
No.
Name
Description
Details
Set by (when
to set)
SM0
Latest diagnostics error
• OFF: No error
• ON: Error
• This relay turns ON when the self-diagnoses returns an
error.
• The ON state is maintained even after the error has
been later cleared.
S (at error
occurrence)
SM1
Latest self-diagnostic error
• OFF: No error
• ON: Error
• This relay turns ON when the self-diagnoses returns an
error.
• The ON state is maintained even after the error has
been later cleared.
S (at error
occurrence)
SM52
battery low
• OFF: Normal
• On: Battery low
• This relay switches to ON when the battery voltage of
the MELIPC drops below the specified value.
• Becomes OFF if the battery voltage becomes normal
later.
• This relay synchronizes with BATTERY LED.
S (at error
occurrence)
SM53
AC/DC DOWN
• Off: No AC/DC DOWN
detection
• On: AC/DC DOWN is detected
This relay switches to ON when a momentary power
failure of 20 ms or less is detected while the AC power
supply module is in use. This relay is reset when power is
turned OFF to ON.
S (at error
occurrence)
SM80
Detailed information 1:
Flag in use
• OFF: Not used
• ON: In use
This relay switches to on if the detailed information 1
exists when SM0 switched to ON.
S (status change)
SM112
Detailed information 2:
Flag in use
• OFF: Not used
• ON: In use
This relay switches to on if the detailed information 2
exists when SM0 switched to ON.
S (status change)
SM1536
Cyclic transmission status
• OFF: Cyclic transmission not
executed
• ON: cyclic transmission carried
out
• This relay turns ON when the cyclic transmission
starts.
• This relay is turned OFF when the cyclic transmission
stops.
S (status change)
SM1540
Data link status
• OFF: All stations normal
• ON: Error station found
• This relay turns ON when an error exists even in one
slave station.
• The status of each slave station can be checked in
SD1540 to SD1543 (Data link status of each station).
S (status change)
Summary of Contents for MELIPC MI5000 Series
Page 1: ...MELIPC MI5000 Series User s Manual Application MI5122 VW ...
Page 2: ......
Page 18: ...16 MEMO ...
Page 22: ...20 1 DIAGNOSTIC AND MAINTENANCE FUNCTIONS 1 1 Watchdog Timer WDT Function MEMO ...
Page 42: ...40 5 iQSS FUNCTION MEMO ...
Page 146: ...144 11 SECURITY FUNCTION 11 3 IP Filter Function MEMO ...
Page 148: ...146 12 MELSOFT PRODUCT AND GOT CONNECTION FUNCTION 12 1 Connection Method MEMO ...
Page 150: ...148 13 SYSTEM COUNT FUNCTION MEMO ...
Page 152: ...150 14 TIMER EVENT FUNCTION MEMO ...
Page 160: ...158 15 OS LINKING FUNCTIONS 15 3 Inter OS Event Notification Function MEMO ...
Page 162: ...160 16 SERIAL INTERFACE SWITCHING FUNCTION MEMO ...
Page 165: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 163 17 Operation related setting Window ...
Page 170: ...168 17 BASIC PARAMETERS 17 1 Basic Parameter List RAS setting Window ...
Page 174: ...172 17 BASIC PARAMETERS 17 1 Basic Parameter List External device connection settings Window ...
Page 313: ...APPX Appendix 10 List of VxWorks Components 311 A MEMO ...
Page 315: ...I 313 MEMO ...
Page 319: ......