APPX
Appendix 8 List of Link Special Registers
271
A
Appendix 8
List of Link Special Registers
This section shows the link special registers of this product.
Range for user ON/OFF and system ON/OFF.
• Range for user ON/OFF: SW0000 to SW001F
• Range for system ON/OFF: SW0020 to SW01FF
Precautions
Do not write data to special registers not listed in the link special register list. Otherwise, there is a risk of a product
malfunction.
No.
Name
Description
SW0000
Link start/stop direction details
Sets data link start/stop direction details
■
00H: Own station
■
01H: All stations
■
02H: Specified station
■
80H: Own station forced (enabled only at start of data link)
■
81H: All station forced (enabled only at start of data link)
■
82H: Specified station forced (enabled only at start of data link)
• Start/stop data link with 'system link start' (SB0002) or 'system link stop' (SB0003).
• 02H: Specified station and 82H: Specified station forced do not include own station.
SW0001 to
SW0008
Link start/stop station specification
When setting 02H: Specified station and 82H: Specified station forced in 'link start/stop specification
details' (SW0000), set the station for data link start/stop.
• 0: No start/stop instruction
• 1: Start/stop instruction
The numbers within the following illustration indicate the station numbers.
SW0010 to
SW0017
Reserved station temporary clear /
temporary error disabled station setting
Specify a slave station to carry out reserved station temporary clear/remove and temporary error
disabled station settings/remove.
• 0: No specification
• 1: Specification
The numbers within the following illustration indicate the station numbers.
<Conditions>
• There is a station for which reserved station temporary clear/remove and temporary error disabled
station settings/remove cannot be specified.
• The status is not stored for the station numbers after the maximum station number.
SW0040
Network No.
Stores the network number of own station.
(Range: 1 to 239)
SW0042
Station No.
Stores the own station's station number.
(Range: 1 to 120, 125 (master station), 255 (station number not set))
SW0043
Own station mode status
Stores own station operational mode settings/communications mode settings.
• 1: Online mode/high-speed mode
• 2: Offline mode
b15
b0
16 15 14 13 12
5
4
3
2
1
32 31 30 29 28
21 20 19 18 17
SW0001
112 111 110 109 108
102 101 100 98 97
-
-
-
125
-
117 116 115 114 113
SW0002
SW0007
SW0008
~
~
~
~
~
b15
b0
16 15 14 13 12
5
4
3
2
1
32 31 30 29 28
21 20 19 18 17
SW0010
112 111 110 109 108
102 101 100 98 97
-
-
-
-
-
117 116 115 114 113
SW0011
SW0016
SW0017
~
~
~
~
~
Summary of Contents for MELIPC MI5000 Series
Page 1: ...MELIPC MI5000 Series User s Manual Application MI5122 VW ...
Page 2: ......
Page 18: ...16 MEMO ...
Page 22: ...20 1 DIAGNOSTIC AND MAINTENANCE FUNCTIONS 1 1 Watchdog Timer WDT Function MEMO ...
Page 42: ...40 5 iQSS FUNCTION MEMO ...
Page 146: ...144 11 SECURITY FUNCTION 11 3 IP Filter Function MEMO ...
Page 148: ...146 12 MELSOFT PRODUCT AND GOT CONNECTION FUNCTION 12 1 Connection Method MEMO ...
Page 150: ...148 13 SYSTEM COUNT FUNCTION MEMO ...
Page 152: ...150 14 TIMER EVENT FUNCTION MEMO ...
Page 160: ...158 15 OS LINKING FUNCTIONS 15 3 Inter OS Event Notification Function MEMO ...
Page 162: ...160 16 SERIAL INTERFACE SWITCHING FUNCTION MEMO ...
Page 165: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 163 17 Operation related setting Window ...
Page 170: ...168 17 BASIC PARAMETERS 17 1 Basic Parameter List RAS setting Window ...
Page 174: ...172 17 BASIC PARAMETERS 17 1 Basic Parameter List External device connection settings Window ...
Page 313: ...APPX Appendix 10 List of VxWorks Components 311 A MEMO ...
Page 315: ...I 313 MEMO ...
Page 319: ......