Appendix 8 List of Link Special Registers
SW00C8
to
SW00CF
Parameter settings status
Stores parameter settings status.
• 0: Stations without parameters set
• 1: Stations with parameters set
The numbers within the following illustration indicate the station numbers. (
: fixed at 0)
<Conditions>
• Enabled when 'baton pass status' of own station (SB0047) is OFF.
• When 'baton pass status of own station' (SB0047) is ON (error), the data immediately before is
retained.
• The status is not stored for the station numbers after the maximum station number.
SW00D0
to
SW00D7
Error disabled station settings status
Stores each station error disabled station settings status.
• 0: Other than error disabled stations
• 1: Error disabled stations
The numbers within the following illustration indicate the station numbers. (
: fixed at 0)
<Conditions>
• Enabled when 'baton pass status of own station' (SB0047) is OFF. When 'baton pass status of own
station' (SB0047) is ON (error), the data immediately before is retained.
• The status is not stored for the station numbers after the maximum station number.
SW00E0
to
SW00E7
Temporary error disabled station
settings status
Stores each station temporary error disabled station settings status.
• 0: Other than temporary error disabled stations
• 1: Temporary error disabled stations
The numbers within the following illustration indicate the station numbers. (
: fixed at 0)
<Conditions>
• Enabled when 'baton pass status' of own station (SB0047) is OFF. When 'baton pass status of own
station' (SB0047) is ON (error), the data immediately before is retained.
• Only enabled for stations with normal 'each station baton pass status' (SW00A0 to SW00A7).
• The status is not stored for the reserved stations and the station numbers after the maximum station
number.
No.
Name
Description
b15
b0
16 15 14 13 12
5
4
3
2
1
32 31 30 29 28
21 20 19 18 17
SW00C8
112 111 110 109 108
102 101 100 98 97
-
-
-
-
-
117 116 115 114 113
SW00C9
SW00CE
SW00CF
~
~
~
~
~
b15
b0
16 15 14 13 12
5
4
3
2
1
32 31 30 29 28
21 20 19 18 17
SW00D0
112 111 110 109 108
102 101 100 98 97
-
-
-
-
-
117 116 115 114 113
SW00D1
SW00D6
SW00D7
~
~
~
~
~
b15
b0
16 15 14 13 12
5
4
3
2
1
32 31 30 29 28
21 20 19 18 17
SW00E0
112 111 110 109 108
102 101 100 98 97
-
-
-
-
-
117 116 115 114 113
SW00E1
SW00E6
SW00E7
~
~
~
~
~
Summary of Contents for MELIPC MI5000 Series
Page 1: ...MELIPC MI5000 Series User s Manual Application MI5122 VW ...
Page 2: ......
Page 18: ...16 MEMO ...
Page 22: ...20 1 DIAGNOSTIC AND MAINTENANCE FUNCTIONS 1 1 Watchdog Timer WDT Function MEMO ...
Page 42: ...40 5 iQSS FUNCTION MEMO ...
Page 146: ...144 11 SECURITY FUNCTION 11 3 IP Filter Function MEMO ...
Page 148: ...146 12 MELSOFT PRODUCT AND GOT CONNECTION FUNCTION 12 1 Connection Method MEMO ...
Page 150: ...148 13 SYSTEM COUNT FUNCTION MEMO ...
Page 152: ...150 14 TIMER EVENT FUNCTION MEMO ...
Page 160: ...158 15 OS LINKING FUNCTIONS 15 3 Inter OS Event Notification Function MEMO ...
Page 162: ...160 16 SERIAL INTERFACE SWITCHING FUNCTION MEMO ...
Page 165: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 163 17 Operation related setting Window ...
Page 170: ...168 17 BASIC PARAMETERS 17 1 Basic Parameter List RAS setting Window ...
Page 174: ...172 17 BASIC PARAMETERS 17 1 Basic Parameter List External device connection settings Window ...
Page 313: ...APPX Appendix 10 List of VxWorks Components 311 A MEMO ...
Page 315: ...I 313 MEMO ...
Page 319: ......