6 CC-Link IE Field Network FUNCTION
6.5 Processing Time
73
6
Transmission delay time of cyclic transmission
This section shows the transmission delay time of cyclic transmission.
When the local station is a C Controller module, change SL to the following processing time.
• SL=P=R+
α
P: Processing time on a C Controller system
R: Refresh cycle
α
: Link refresh time
When the local station is this product, use direct access to the link device or buffer memory access. Change
SL to the processing time of the function.
In case of a master station and intelligent device station / remote device station
■
Master station (RX, RWr)
←
intelligent device station/remote device station (input)
Times are shown below.
• The time from signal input into the intelligent device station / remote device station until the link device of the master station
is turned ON or OFF
• The time from data input into the intelligent device station / remote device station until data is stored in the link device of the
master station
CT: Synchronous communication cycle
Rio: Processing time of intelligent device station / remote device station (
Manual of intelligent device station / remote
device station being used)
■
Master station (RY, RWw)
→
intelligent device station/remote device station (output)
Times are shown below.
• The time from when the link device of the master station is turned ON or OFF until the output of the intelligent device station
/ remote device station is turned ON or OFF.
• The time from data setting to the link device of the master station until data is output to the intelligent device station / remote
device station
CT: Synchronous communication cycle
Rio: Processing time of intelligent device station / remote device station (
Manual of intelligent device station / remote
device station being used)
Calculated value
Transmission delay time (no block data assurance per station setting)
Normal value
(CT
×
1)+Rio
Maximum value
(CT
×
2)+Rio
Calculated value
Transmission delay time (no block data assurance per station setting)
Normal value
(CT
×
1)+Rio
Maximum value
(CT
×
2)+Rio
Summary of Contents for MELIPC MI5000 Series
Page 1: ...MELIPC MI5000 Series User s Manual Application MI5122 VW ...
Page 2: ......
Page 18: ...16 MEMO ...
Page 22: ...20 1 DIAGNOSTIC AND MAINTENANCE FUNCTIONS 1 1 Watchdog Timer WDT Function MEMO ...
Page 42: ...40 5 iQSS FUNCTION MEMO ...
Page 146: ...144 11 SECURITY FUNCTION 11 3 IP Filter Function MEMO ...
Page 148: ...146 12 MELSOFT PRODUCT AND GOT CONNECTION FUNCTION 12 1 Connection Method MEMO ...
Page 150: ...148 13 SYSTEM COUNT FUNCTION MEMO ...
Page 152: ...150 14 TIMER EVENT FUNCTION MEMO ...
Page 160: ...158 15 OS LINKING FUNCTIONS 15 3 Inter OS Event Notification Function MEMO ...
Page 162: ...160 16 SERIAL INTERFACE SWITCHING FUNCTION MEMO ...
Page 165: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 163 17 Operation related setting Window ...
Page 170: ...168 17 BASIC PARAMETERS 17 1 Basic Parameter List RAS setting Window ...
Page 174: ...172 17 BASIC PARAMETERS 17 1 Basic Parameter List External device connection settings Window ...
Page 313: ...APPX Appendix 10 List of VxWorks Components 311 A MEMO ...
Page 315: ...I 313 MEMO ...
Page 319: ......