17 BASIC PARAMETERS
17.1 Basic Parameter List
169
17
Displayed items
■
WDT (Watchdog Timer) settings (VxWorks part)
■
WDT (Watchdog Timer) setting (Windows part)
■
MELIPC operation upon error detection setting
■
LED display setting
■
Event history settings
Item
Description
Setting range
parameter
No.
System WDT
settings
Set the system WDT setting (VxWorks part).
3500H
Monitoring time
Set the system WDT monitoring time.
20 to 2000 [ms](10 ms
units)
(Default: 1,000 ms)
Item
Description
Setting range
parameter
No.
System WDT
settings
Set the system WDT setting (Windows part).
6E11H
Monitoring time
Set the system WDT monitoring time.
1 to 600 (s) (1 s units)
(Default: 5 s)
Item
Description
Setting range
parameter
No.
MELIPC temperature error
Set the device operation upon detection of a Main module temperature
error.
If "Shutdown" is set, the VxWorks part and Windows part shut down
when an error is detected.
• Shut down
• Do not shut down
(Default: Shutdown)
3501H
Windows part stop
Set operation of the Windows part when a stop state is detected due to
a Windows bluescreen, timeout detection from the Windows part
system watchdog timer.
• Do not restart
• Restart
(Default: Do not restart)
Item
Description
Setting range
parameter
No.
MAIN ERR
LED
Configure the display of the MAIN ERR LED.
3502H
Minor error
(Continue error)
Set MAIN ERR LED to "Display" or "Do not display" when a minor error
(continuation error) is detected.
• Display
• Do not display
(Default: Display)
Item
Description
Setting range
parameter
No.
Save-capacity settings
Set the storage capacity per event history file.
Setting a large save quantity enable saving of a larger number of
events.
2 to 2048 (KB) (1 KB units)
(Default: 128 KB)
3504H
Summary of Contents for MELIPC MI5000 Series
Page 1: ...MELIPC MI5000 Series User s Manual Application MI5122 VW ...
Page 2: ......
Page 18: ...16 MEMO ...
Page 22: ...20 1 DIAGNOSTIC AND MAINTENANCE FUNCTIONS 1 1 Watchdog Timer WDT Function MEMO ...
Page 42: ...40 5 iQSS FUNCTION MEMO ...
Page 146: ...144 11 SECURITY FUNCTION 11 3 IP Filter Function MEMO ...
Page 148: ...146 12 MELSOFT PRODUCT AND GOT CONNECTION FUNCTION 12 1 Connection Method MEMO ...
Page 150: ...148 13 SYSTEM COUNT FUNCTION MEMO ...
Page 152: ...150 14 TIMER EVENT FUNCTION MEMO ...
Page 160: ...158 15 OS LINKING FUNCTIONS 15 3 Inter OS Event Notification Function MEMO ...
Page 162: ...160 16 SERIAL INTERFACE SWITCHING FUNCTION MEMO ...
Page 165: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 163 17 Operation related setting Window ...
Page 170: ...168 17 BASIC PARAMETERS 17 1 Basic Parameter List RAS setting Window ...
Page 174: ...172 17 BASIC PARAMETERS 17 1 Basic Parameter List External device connection settings Window ...
Page 313: ...APPX Appendix 10 List of VxWorks Components 311 A MEMO ...
Page 315: ...I 313 MEMO ...
Page 319: ......