M70V Series Connection Manual
2.5 Operation Panel I/O Unit
45
<Input/output circuit>
(11) Remote I/O unit I/F (RIO3)
<Cable side connector type>
Connector: 1-178288-3
Contact: 1-175218-2 x3
Recommended manufacturer: Tyco Electronics
Refer to the following chart for the maximum number of connecting stations and I/O points.
(Note)
Refer to the section "General Specifications: Remote I/O Unit" for the number of occupying stations and I/
O points of remote I/O units.
(12) Control unit I/F (CG71)
1
I/O
TXRX3
2
I/O
TXRX3*
3
0V(GND)
Operation panel I/O unit type
Max. number of stations
(RIO3 connection)
Max. number of I/O points
(RIO3 connection)
FCU7-DX710/DX711
4 stations
(stations 3rd to 6th can be used)
128 points/128 points
FCU7-DX720/DX721/DX730/DX731
3 stations
(stations 4th to 6th can be used)
96 points/96 points
0V
+5V
4
3
14
13
10
20
1
11
0V
+5V
+5V
+5V
0V
0V
0V
6
16
+12V
+12V
5V
12V
HA1A
HA2A
HA1B
HA2B
Connector
pin No.
Signal
input
Power
output
Power
output
Control
unit
1
3
Summary of Contents for M70V Series
Page 1: ......
Page 13: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 25: ......
Page 26: ...1 1 System Configuration ...
Page 36: ...11 2 General Specifications ...
Page 110: ...85 3 Installation ...
Page 120: ...95 4 Connection ...
Page 173: ...4 Connection MITSUBISHI CNC 148 ...
Page 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Page 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Page 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Page 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Page 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Page 246: ......
Page 250: ......