M70V Series Connection Manual
1.3 List of Configuration
9
1.3.4 List of Cables
Type
Application
Length (m) of cables provided
by Mitsubishi
Max. cable
length
CNP2E-1-xM
Motor side PLG cable
Spindle side accuracy detector
TS5690 cable
2, 3, 4, 5, 7, 10, 15, 20, 25, 30
30m
CNP3EZ-2P-xM
Spindle side detector cable
OSE-1024 cable
2, 3, 4, 5, 7, 10, 15, 20, 25, 30
30m
CNP3EZ-3P-xM
Spindle side detector cable
OSE-1024 cable
2, 3, 4, 5, 7, 10, 15, 20, 25, 30
30m
CNV22J-K1P-0.3M
For HF-KP (Servo) Motor side detector relay cable (motor side)
Lead out in direction of motor shaft
Compatible with only IP65
0.3
0.3m
CNV22J-K2P-0.3M
For HF-KP (Servo) Motor side detector relay cable (motor side)
Lead out in opposite direction of motor shaft
Compatible with only IP65
0.3
0.3m
CNV2E-6P-xM
Motor side detector cable (for A51/A74N(/A74)) /
Ball screw side detector cable
2, 3, 4, 5, 7, 10, 15, 20, 25, 30
30m
CNV2E-7P-xM
Motor side detector cable (for A51/A74N(/A74)) /
Ball screw side detector cable
2, 3, 4, 5, 7, 10, 15, 20, 25, 30
30m
CNV2E-8P-xM
For HF/HF-H, HF-KP (Tool spindle) Motor side detector cable (for A48/
A51/A74N(/A74)) /
For HF-KP (Servo) Motor side detector relay cable (Drive unit side)
2, 3, 4, 5, 7, 10, 15, 20, 25, 30
30m
CNV2E-9P-xM
For HF/HF-H, HF-KP (Tool spindle) Motor side detector cable (for A48/
A51/A74N(/A74))
2, 3, 4, 5, 7, 10, 15, 20, 25, 30
30m
CNV2E-D-xM
MDS-B-SD unit cable
2, 3, 4, 5, 7, 10, 15, 20, 25, 30
30m
CNV2E-HP-xM
MDS-B-HR unit cable
2, 3, 4, 5, 7, 10, 15, 20, 25, 30
30m
CNV2E-K1P-xM
For HF-KP (Servo) Motor side detector cable
Lead out in direction of motor shaft
Compatible with only IP65
2, 3, 5, 7, 10
10m
CNV2E-K2P-xM
For HF-KP (Servo) Motor side detector cable
Lead out in opposite direction of motor shaft
Compatible with only IP65
2, 3, 5, 7, 10
10m
DG21-xM
Battery cable
(For drive unit - battery unit)
0.3, 0.5, 1, 5
5m
DG22-xM
Battery cable
(For drive unit - drive unit)
(Note) This cable is required to supply the power from the battery unit to
multiple drive units.
0.3, 0.5, 1, 2, 3, 5, 7, 10
10m
DG23-xM
Battery cable
(For drive unit - battery box)
(Note) The battery box side is connected using a bare conductor or a
terminal bar.
0.3, 0.5, 1, 2, 3, 5, 7, 10
10m
DG24-xM
5V supply / DO output cable
(For drive unit - battery box)
(Note) The battery box side is connected using a bare conductor or a
terminal bar.
0.3, 0.5, 1, 2, 3, 5, 7, 10
10m
F023 LxM
Manual pulse generator cable (5V): 1ch
(for connection to operation panel I/O unit)
1, 2, 3, 5, 8, 10, 15, 20
20m
F024 LxM
Manual pulse generator cable (5V): 2ch
(for connection to operation panel I/O unit)
1, 2, 3, 5, 8, 10, 15, 20
20m
F034 LxM
RS-232C I/F cable: 1ch (for control unit)
0.5, 1, 2, 3, 5, 8, 10
15m (*)
F035 LxM
RS-232C I/F cable: 2ch (for control unit)
0.5, 1, 2, 3, 5, 8, 10
15m (*)
F070 LxM
24VDC power cable
0.5, 1.5, 3, 5, 8, 10, 15, 20
30m
F110 LxM
24VDC power cable for PD25/PD27
0.5, 1.5, 3, 5, 8, 10, 15
15m
F120 LxM
Emergency stop cable
0.5, 1.5, 3, 5, 8, 10, 15, 20
30m
F170 LxM
ON/OFF switch cable for PD25/PD27
0.5, 1.5, 3, 5, 8, 10, 15
15m
F221 LxM
Analog output cable
1, 2, 3, 5, 8, 10, 15, 20
30m
F320 LxM
Manual pulse generator cable (12V): 1ch
(for connection to operation panel I/O unit)
1, 2, 3, 5, 8, 10, 15, 20
50m
F321 LxM
Manual pulse generator cable (12V): 2ch
(for connection to operation panel I/O unit)
1, 2, 3, 5, 8, 10, 15, 20
50m
F351
DI/DO cable (one side connector)
(for operation panel I/O unit)
3
50m
FCUA-R030-xM
SKIP input cable
3, 7
20m
FCUA-R031-xM
Analog input/output cable (for remote I/O unit)
2, 3, 7
30m
FCUA-R050-xM
Synchronous encoder - control unit (straight, with connector)
5
30m
FCUA-R054-xM
Synchronous encoder - control unit (right angle, with connector)
3, 5, 10, 15, 20
30m
Summary of Contents for M70V Series
Page 1: ......
Page 13: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 25: ......
Page 26: ...1 1 System Configuration ...
Page 36: ...11 2 General Specifications ...
Page 110: ...85 3 Installation ...
Page 120: ...95 4 Connection ...
Page 173: ...4 Connection MITSUBISHI CNC 148 ...
Page 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Page 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Page 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Page 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Page 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Page 246: ......
Page 250: ......