M70V Series Connection Manual
4.4 Connection of Remote I/O Unit
137
4.4.3 Connecting FCUA-DX10x/14x Unit with Machine Control Signal
<Outline of connection>
Type of machine input/output signal and
number of points
Input
Output
32 points
32 points
CAUTION
1. Connect the cable to the designated connector. Incorrect connections could damage the device.
2. Do not connect or disconnect the connection cables between each unit while the power is ON.
DI-L
DO-L
FCUA-R300 /
FCUA-R301
FCUA-R300 /
FCUA-R301
Machine
signal
Machine
signal
FCUA-DX10x
or
FCUA-DX14x
DI-L
FCUA-DX100/140
COM
A3
B3
B1
B2
A1
A2
B1
B2
A1
A2
DO-L
DCIN
0V FG
1 2 3
RIO2
RIO1
FG
DI-L
FCUA-DX101/141
COM
A3
B3
B1
B2
A1
A2
B1
B2
A1
A2
DO-L
RA
R
PL
DCIN
0V FG
1 2 3
RIO2
RIO1
FG
RA
R
PL
0V
(RG)
0V(RG)
0V(RG)
24VDC(+)
24VDC(+)
24VDC(+)
24VDC(+)
24VDC(+)
Machine
control panel
Input circuit
Sink type
Output circuit
Sink type
Control
circuit
Stabilized power supply
Stabilized power supply
Machine
control panel
Input circuit
Sink type
Output circuit
Sink type
Control
circuit
Connection to 24V common (example)
Connection to 0V common (example)
Summary of Contents for M70V Series
Page 1: ......
Page 13: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 25: ......
Page 26: ...1 1 System Configuration ...
Page 36: ...11 2 General Specifications ...
Page 110: ...85 3 Installation ...
Page 120: ...95 4 Connection ...
Page 173: ...4 Connection MITSUBISHI CNC 148 ...
Page 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Page 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Page 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Page 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Page 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Page 246: ......
Page 250: ......