Appendix 1 Cable
MITSUBISHI CNC
176
Appendix 1.25 FCUA-R050/R054 Cable
Max. cable length: 30m
Application: Synchronous encoder - control unit
(Note)
Fold the cable shield over the sheath, and wrap copper foil tape over it. Connect the wound copper foil
tape to GND plate of the connector.
[ENC1]
Plug: 10120-3000VL
Shell: 10320-52F0-008
Recommended manufacturer: 3M
Wire material: UL1061-2464
AWG24
×
12P
Recommended manufacturer:
Oki Electric Cable
[FCUA-R050 cable]
Connector: MS3106B20-29S
Cable clamp: MS3057-12A
Recommended manufacturer:
ITT Cannon
[FCUA-R054 cable]
Connector: MS3108B20-29S
Cable clamp: MS3057-12A
Recommended manufacturer:
ITT Cannon
ENC
FCUA-R050
FCUA-R054
ENC1A (ENC2A)
ENC1A*(ENC2A*)
ENC1B (ENC2B)
ENC1B*(ENC2B*)
ENC1Z (ENC2Z)
ENC1Z*(ENC2Z*)
GND
GND
+5V
+5V
A
N
C
R
B
P
K
ENC1
4
14
3
13
2
12
1
11
10
20
H
FG
Summary of Contents for M70V Series
Page 1: ......
Page 13: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 25: ......
Page 26: ...1 1 System Configuration ...
Page 36: ...11 2 General Specifications ...
Page 110: ...85 3 Installation ...
Page 120: ...95 4 Connection ...
Page 173: ...4 Connection MITSUBISHI CNC 148 ...
Page 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Page 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Page 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Page 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Page 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Page 246: ......
Page 250: ......