4 Connection
MITSUBISHI CNC
108
(2) When using two or more power supply units within a single NC communication bus system
Two or more power supply units may be required within a single NC communication bus system if the spindle drive
unit capacity is large. The drive unit receiving power (L+, L-) from each power supply unit must always have NC
communication cable connection at the NC side of each power supply unit. In the NC communication bus
connection example below, power supply [1] cannot supply power (L+, L-) to the 5th axis servo drive unit.
For basic connection information, refer to "(1) When using one power supply unit".
Connections when using two power supply units within a single NC communication bus system
CAUTION
1. The drive unit receiving power (L+, L-) from each power supply unit must always have NC communication bus
connection at the NC side of each power supply unit.
2. If two or more power supply units are connected in the drive system, confirm that the units are not connected
with each other through the L+ and L- lines before turning ON the power. Also make sure that the total capacity
of the drive units connected to the same power supply unit meets the unit's selected capacity.
CN4
CN4
CN4
CN4
Power
cannot be
supplied
Optical
communication
cable
MDS-D2/DH2-SP
8th axis
(CV control axis)
MDS-D2/DH2-CV
[2]
MDS-D2-SP2
6th/7th axis
MDS-D2/DH2-V2
1st/2nd axis
MDS-D2/DH2-V2
3rd/4th axis
(CV control axis)
MDS-D2/DH2-CV
[1]
MDS-D2/DH2-V1
5th axis
Connected
to the NC
Summary of Contents for M70V Series
Page 1: ......
Page 13: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 25: ......
Page 26: ...1 1 System Configuration ...
Page 36: ...11 2 General Specifications ...
Page 110: ...85 3 Installation ...
Page 120: ...95 4 Connection ...
Page 173: ...4 Connection MITSUBISHI CNC 148 ...
Page 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Page 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Page 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Page 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Page 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Page 246: ......
Page 250: ......