Graphic Operation Terminal F930GOT
Additional Functions (in V.2.00 or later) 13
13-9
13.3.2
Setting of communication
•
Setting of RS-232C (channel 0) parameters
Set the system mode driver (DF1) to "half-duplex slave (DF1)".
Set other parameters to the default values (initial values).
•
Channel configuration of DF1 (half-duplex slave)
Set the parameters as shown in the table below.
Set all parameters except shaded ones to the default values.
•
Setting on the GOT side
When the connected PLC is set to "SLC500 Series" in the screen creation software or "SET-
UP MODE" in the GOT, the following setting is selected.
(The following setting is automatically selected when the PLC model is set to "SLC500
Series". You do not have to set them manually.)
Parameter
Set value
Diagnostic File
Baud Rale
19200
Parity
Even
Duplicate Packet Delection
Disabled
Station Address
0
Error Delection
BCC
Poll Timeout
50
RTS Off Delay
0
RTS Send Delay
0
Message Retries
3
Control Line
No Handshaking
EOT Suppression
No
Baud rate
19200
Data length
8 bits
Stop bit
1 bit
Parity bit
even
Control method
None
Summary of Contents for F930GOT-BWD-E
Page 1: ...USER S MANUAL F930GOT BWD E ...
Page 4: ...Graphic Operation Terminal F930GOT ii ...
Page 6: ...Graphic Operation Terminal F930GOT iv ...
Page 14: ...vi ...
Page 60: ...Graphic Operation Terminal F930GOT Start up 2 2 10 MEMO ...
Page 68: ...Graphic Operation Terminal F930GOT Screen Mode 3 3 8 MEMO ...
Page 120: ...Graphic Operation Terminal F930GOT Creation of Display Screens 8 8 30 ...
Page 200: ...Graphic Operation Terminal F930GOT Changeover of Display Screen FX PCS DU WIN E 10 10 18 ...
Page 272: ...Graphic Operation Terminal F930GOT Additional Functions in V 2 00 or later 13 13 24 MEMO ...