Graphic Operation Terminal F930GOT
Changeover of Display Screen (FX-PCS-DU/WIN-E) 10
10-2
10.2
"Change Screen" object
Use the "Change Screen" object to change over screens.
The "Change Screen" object is important. It allows to specify a screen to be displayed next
after the currently displayed screen when the trigger condition (operation key in the GOT and
bit device in the PLC) is satisfied.
10.2.1
Contents of setting
In the "Change Screen" object, the following three main items are to be set.
1) Condition
Set the condition which triggers screen changeover.
2) Destination Screen
Set the destination screen to be displayed when the trigger condition is satisfied.
3) Save Current Screen
Set whether or not the screen No. of the currently displayed screen is to be stored in the
memory before screen changeover.
Condition
Set the condition to trigger screen changeover.
An operation key in the GOT and a bit device in the PLC can be set here. When both of
them are satisfied, the display screen is changed over.
When both "Control Input" and "Bit Device" are satisfied, the display screen is changed over.
Set item
Description
Control Input
(in GOT)
Touch key
Common setting for all screens: Touch keys Nos.
50 to 99
Setting for individual screen: Touch keys Nos. 0 to 49
None
There is no condition for operation key.
Bit Device
(in PLC)
Bit device
Bit device X, Y, M, S, T or C (a contact or b contact)
None
(Always Change)
There is no condition for PLC.
50 keys
in total
Summary of Contents for F930GOT-BWD-E
Page 1: ...USER S MANUAL F930GOT BWD E ...
Page 4: ...Graphic Operation Terminal F930GOT ii ...
Page 6: ...Graphic Operation Terminal F930GOT iv ...
Page 14: ...vi ...
Page 60: ...Graphic Operation Terminal F930GOT Start up 2 2 10 MEMO ...
Page 68: ...Graphic Operation Terminal F930GOT Screen Mode 3 3 8 MEMO ...
Page 120: ...Graphic Operation Terminal F930GOT Creation of Display Screens 8 8 30 ...
Page 200: ...Graphic Operation Terminal F930GOT Changeover of Display Screen FX PCS DU WIN E 10 10 18 ...
Page 272: ...Graphic Operation Terminal F930GOT Additional Functions in V 2 00 or later 13 13 24 MEMO ...