M800/M80/E80 Series Maintenance Manual
1 System Basic Configuration
9
IB-1501273-F
Non-Windows-based display (8.4-type/10.4-type/15-type)
(Note 1) For information on how to connect the drive unit, refer to the drive unit's manual.
(Note 2) When connecting a remote I/O unit to the 3rd RIO channel, insert it between the control unit and operation panel I/O unit.
(Note 3) There is no need to connect a terminator R2-TM to the graphic control unit.
(Note 4) For the 8.4-type display unit, TP connector is not used.
(1) For the connection of MITSUBISHI CNC machine operation panel, refer to "M800W/M80W Series Connection and Set-
up Manual".
(2) When the handle of handy terminal is used, connect ENC connector of G430 cable to MPG connector of the operation
panel I/O unit.
Because the pin assignment of ENC connector of G430 is different from that of MPG connector of the operation panel
I/O unit, conversion is required.
The conversion cable needs to be prepared by the MTB.
SIO
1ch
:
J030
2ch
:
J031
2ch
RS232C
SKIP
RIO2
SD
RIO3
GDI
LAN
J303
Network
FCU8-EX56x
J100
SD
FCU8-DX2xx/DX6xx/DX4xx
RIO1
DCIN
J070/071
(EcoMonitor)
OPTH1
OPTH2
J395/J396
J395/J396
EMG
J120
Max. 8 points
J070/071
J070/071
J210
DI:CJ31/33
DO:CJ32/34
RIO1
DCIN
RIO2
DI:CJ31/33
DO:CJ32/34
RIO1
DCIN
RIO2
J350/351
J350/351
J070/071
J070/071
J210
DI:CJ31/33
DO:CJ32/34
RIO1
DCIN
RIO2
DI:CJ31/33
DO:CJ32/34
RIO1
DCIN
RIO2
J350/351
J350/351
(R2-TM)
(R2-TM)
FG
5V
:
J023/J024/J025
12V
:
J020/J021/J022
L1 L2 L3
(NFB)
DCOUT
FG
ACIN
CP
MC
ON
OFF
MC
MC
J350/351
J350/351
J350/351
J350/351
FCU8-EX54x
EXT1
EXT3
G430
device
Skip signal input
Communication
expansion unit
Control unit
Max. 32 units for each port
Remote I/O unit
Remote I/O unit
Remote I/O unit
Remote I/O unit
24VDC
Energy measuring units
Drive units
Stored in control unit
To the next
remote I/O or
terminator
connector
To the next
remote I/O or
terminator
connector
Emergency
stop switch
SD
memory
card
24VDC
24VDC
24VDC
24VDC
Machine
control
relay/contact
Machine
control
relay/contact
24VDC
Manual pulse
generator (5V/12V)
Machine operation
panel made by the
machine tool builder
Dotted lines indicate the sections prepared by the machine tool builder.
<> Angle brackets indicates attached cable of unit.
No-fuse breaker
24VDC stabilized
power supply
Function
expansion unit
(Note 1)
Handy terminal
FCU8-MU044
RIO4/M
BTBOX
J070/071
DI:CJ31/33
DO:CJ32/34
RIO1
DCIN
RIO2
<J09x>
USB_F
SDC_F
USB_B
SDC_B
<J08x>
FCU8-GC211
RIO3EXT
RS232C
CJ71
FCU8-DX730
CG31
MPG
CG32
NCKB
CG33
CG34
LAN1
J303
Network
LAN2
J303
J210
G402
J210
EMG
DCIN
J070/071
LCD
MENUKEY
TP
BL
FRONT
ENC
ON
OFF
CJ71
J010
SIO
FCU8-DX2xx/DX6xx/DX4xx
max. 29 units
J170
<J421>
RIO1
J210
FCU8-KB92x
FCU8-KB941/KB931
<G460>
24VDC
MITSUBISHI CNC Machine Operation Panel
24VDC
Remote I/O unit
(Note 2)
Emergency
stop switch
Graphic control unit
device
24VDC
24VDC
Operation panel I/O unit
Menu key
Display unit
Memory mediums
Front memory I/F card
Keyboard unit
(Note 3)
(Note 4)
8.4
-type
:FCU8-DU121-12
FCU8-KB02x/04x/083
10.4-type:FCU8-DU141-32
15-type:FCU8-DU181-32
Note
Summary of Contents for E80 Series
Page 1: ......
Page 7: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 28: ...1 1 IB 1501273 F System Basic Configuration ...
Page 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Page 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Page 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Page 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Page 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Page 166: ...5 139 IB 1501273 F Troubleshooting ...
Page 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Page 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Page 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Page 212: ......