M800/M80/E80 Series Maintenance Manual
1 System Basic Configuration
8
IB-1501273-F
Windows-based display (19-type)
(Note 1) For information on how to connect the drive unit, refer to the drive unit's manual.
(1) For the connection of MITSUBISHI CNC machine operation panel, refer to "M800W/M80W Series Connection and Set-
up Manual".
(2) When the handle of handy terminal is used, connect ENC connector of G430 cable to MPG connector of the operation
panel I/O unit.
Because the pin assignment of ENC connector of G430 is different from that of MPG connector of the operation panel
I/O unit, conversion is required.
The conversion cable needs to be prepared by the MTB.
SIO
1ch
:
J030
2ch
:
J031
2ch
RS232C
SKIP
RIO2
SD
RIO3
GDI
LAN
J303
Network
FCU8-EX56x
J100
SD
FCU8-DX2xx/DX6xx/DX4xx
RIO1
DCIN
J070/071
(EcoMonitor)
OPTH1
OPTH2
J395/J396
J395/J396
EMG
J120
Max. 8 points
J070/071
J070/071
J210
DI:CJ31/33
DO:CJ32/34
RIO1
DCIN
RIO2
DI:CJ31/33
DO:CJ32/34
RIO1
DCIN
RIO2
J350/351
J350/351
J070/071
J070/071
J210
DI:CJ31/33
DO:CJ32/34
RIO1
DCIN
RIO2
DI:CJ31/33
DO:CJ32/34
RIO1
DCIN
RIO2
J350/351
J350/351
(R2-TM)
(R2-TM)
FG
5V
:
J023/J024/J025
12V
:
J020/J021/J022
L1 L2 L3
(NFB)
DCOUT
FG
ACIN
CP
MC
ON
OFF
MC
MC
J350/351
J350/351
J350/351
J350/351
FCU8-EX54x
EXT1
EXT3
G430
device
Skip signal input
Communication
expansion unit
Control unit
Max. 32 units for each port
Remote I/O unit
Remote I/O unit
Remote I/O unit
Remote I/O unit
24VDC
Energy measuring units
Drive units
Stored in control unit
To the next
remote I/O or
terminator
connector
To the next
remote I/O or
terminator
connector
Emergency
stop switch
SD
memory
card
24VDC
24VDC
24VDC
24VDC
Machine
control
relay/contact
Machine
control
relay/contact
24VDC
Manual pulse
generator (5V/12V)
Machine operation
panel made by the
machine tool builder
Dotted lines indicate the sections prepared by the machine tool builder.
<> Angle brackets indicates attached cable of unit.
No-fuse breaker
24VDC stabilized
power supply
Function
expansion unit
(Note 1)
Handy terminal
FCU8-MU044
RIO4/M
BTBOX
J120
ON/OFF
CFAST
CFast
LVDS1
USB2-1
USB2-2
FCU8-PC231
LAN
J303
MENUKEY
RIO3EXT
ON
OFF
G170
MPG
INV
RS232C
USB-RS232C
GDI
KEYUSB
RIO3
J303
NCKB
KEYUSB
J210
J291
J210
LVDS2
SD
DCIN
J070/071
EMG
USB
USB3-2
USB3-1
USB2-4
USB2-3
USB2-6
USB2-5
FCU8-DX2xx/DX6xx/DX4xx
CJ71
FCU8-CF001-001
DCIN
J070/071
Network
CG31
CG32
FCU8-DX830/837
CG33
CG34
SDI
Max. 8 points
DI:CJ31/33
DO:CJ32/34
RIO1
DCIN
RIO2
J350/351
J350/351
(R2-TM)
J210
FCU8-KB92x
FCU8-KB941/KB931
<G460>
24VDC
MITSUBISHI CNC Machine Operation Panel
Emergency
stop switch
Personal computer unit
device
conversion
24VDC
USB memory
24VDC
Remote I/O unit
24VDC
Operation panel I/O unit
Safety signal input
DX830
:
No safety signal input
DX837
:
With safety signal input
Stored in
personal computer unit
CFast unit
(Safety signal input is
DX837 only.)
To the next remote I/O
or terminator connector
Added onto back of
display unit
SD
memory
card
24VDC
Machine
control
relay/contact
Backlight
I/F PCB
<J09x>
<J292>
<J190>
<J290>
<G195>
<J420>
FCU8-EP201-2
USB
SD
PCUSB
19-type LCD
Side memory I/F unit
wth touch panel
Display unit
FCU8-DU191-77
FCU8-DU192-77
Note
Summary of Contents for E80 Series
Page 1: ......
Page 7: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 28: ...1 1 IB 1501273 F System Basic Configuration ...
Page 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Page 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Page 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Page 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Page 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Page 166: ...5 139 IB 1501273 F Troubleshooting ...
Page 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Page 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Page 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Page 212: ......