M800/M80/E80 Series Maintenance Manual
6 Replacing Each Unit
170
IB-1501273-F
6.9 Communication Expansion Unit
Always install the expansion unit (FCU8-EX56x) with the machine power turned OFF.
(1) Check that the machine power is turned OFF. (If the power is not OFF, turn it OFF.)
(2) Open the electric cabinet door.
(3) Push the tabs at the top and bottom of the cover attached to the expansion slot of the control unit.
(4) Remove the cover of the expansion slot.
(5) Insert the expansion unit into the expansion slot.
(6) Push the expansion unit firmly until it is fixed with the tabs.
(7) Connect the cable to the expansion unit.
(8) Confirm that all the cables are correctly connected and close the electric cabinet door.
(Note) On FCU8-EX565, EtherNet/IP function is supported by the "LAN1" port only. LAN2 does not support EtherNet/IP
function.
(1) Check that the machine power is turned OFF. (If the power is not OFF, turn it OFF.)
(2) Open the electric cabinet door.
(3) Disconnect the cable from the expansion unit.
(4) Press the tabs on the top and bottom of the expansion unit.
(5) Remove the expansion unit by pulling it frontward.
(6) Install the cover to the expansion slot.
(7) Close the electric cabinet door.
Always install the expansion unit (FCU8-EX56x) with the machine power turned OFF.
(1) Check that the machine power is turned OFF. (If the power is not OFF, turn it OFF.)
(2) Open the operation panel.
(3) Disconnect the LAN cable and SIO cable of control unit to facilitate the installation.
(4) Remove the back cover of the control unit.
(5) Insert the expansion unit into the option relay unit for communication expansion (FCU8-EX70x).
You need to open and close the cover to insert the unit into the option relay unit (FCU8-EX703).
(6) Fix the expansion unit to the control unit with three screws of M3 x 25.
(7) Connect the cable to the expansion unit.
(8) Connect the LAN cable and SIO cable to the control unit.
(9) Confirm that all the cables are correctly connected and close the operation panel.
CAUTION
1. Incorrect connections could cause devices to damage. Connect the cables to designated connectors.
2. Do not replace the operation panel I/O unit while the power is ON.
3. Do not connect or disconnect the cables between units while the power is ON.
Installation procedures (M800W/M80W)
Removal procedures (M800W/M80W)
Installation procedures (M800S/M80/E80)
Summary of Contents for E80 Series
Page 1: ......
Page 7: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 28: ...1 1 IB 1501273 F System Basic Configuration ...
Page 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Page 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Page 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Page 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Page 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Page 166: ...5 139 IB 1501273 F Troubleshooting ...
Page 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Page 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Page 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Page 212: ......