M800/M80/E80 Series Maintenance Manual
3 Maintenance of the Drive Unit
57
IB-1501273-F
3.3.1.3 Replacing the Battery
Replacing parts
<Replacing a battery equipped with the spindle/servo drive unit or the battery unit, MDSBTBOX-LR2060>
When the battery voltage is low (warning 9F), place an order for the same type of a battery as the one currently equipped
with the unit.
Battery type LR20 is commercially available as a size-D alkaline battery. The battery may be purchased and replaced by
the user.
(1) Four LR20 size-D alkaline batteries are needed for per battery unit, MDSBTBOX-LR2060.
Type
Battery equipped unit
MDS-BAT6V1SET
Servo drive unit
LR20 (size-D alkaline battery)
Battery unit, MDSBTBOX-LR2060
CAUTION
1. When the battery voltage is low (warning 9F), do not shut OFF the power of the drive unit until replacement of the
battery to protect the data.
2. Replace the MDSBTBOX-LR2060 battery with new batteries (LR20) that is within the recommended service period.
Note
Summary of Contents for E80 Series
Page 1: ......
Page 7: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 28: ...1 1 IB 1501273 F System Basic Configuration ...
Page 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Page 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Page 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Page 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Page 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Page 166: ...5 139 IB 1501273 F Troubleshooting ...
Page 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Page 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Page 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Page 212: ......