M800/M80/E80 Series Maintenance Manual
1 System Basic Configuration
32
IB-1501273-F
1.4.6.3 Display when an Alarm Occurs
If an alarm occurs, these LEDs show both the occurrence and the meaning of the alarm in two stages.
At first,
flashes three times. In case of stop code,
is shown instead.
Then, the meaning of the alarm is indicated in three different stages.
[Transition of 7-segment LED display]
[Example of alarm display for 2-part systems]
In normal state
When Alarm (Stop code) occurs
flashes three times
Alarm code is shown in three different stages.
Example) Z53 CNC overheat 0003
When Alarm (Stop code) occurs
flashes three times
- Flashes when an alarm occurs in the 1st part system
-
Flashes when an alarm occurs in the 2nd part system
When an alarm doesn't occur
in the 1st part system
This means that indicated alarm
belongs to the 1st part system.
Alarm code is shown in three
steps.
Example
)
M01
H/W stroke end axis exists
0006 XYZ
When an alarm doesn't occur
in the 2nd part system
This means that indicated alarm
belongs to the 2nd part system.
Alarm code is shown in three
steps.
Example)
P232 No. program No.
Summary of Contents for E80 Series
Page 1: ......
Page 7: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 28: ...1 1 IB 1501273 F System Basic Configuration ...
Page 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Page 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Page 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Page 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Page 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Page 166: ...5 139 IB 1501273 F Troubleshooting ...
Page 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Page 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Page 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Page 212: ......