M800/M80/E80 Series Maintenance Manual
3 Maintenance of the Drive Unit
67
IB-1501273-F
(b) Replacing the built-in battery
Cancel the warning 9F by executing an alarm reset (pushing the NC reset button).
MR-BAT6V1
MR-BAT6V1SET that reached the end of the life can be reused
by replacing the MR-BAT6V1 battery.
Open the cover while pushing the locking part.
Replace the built-in battery with a new battery
for MR-BAT6V1.
Close the cover by pushing until it is fixed
with the tab of the locking part.
Cover
Locking part
Tab