M800/M80/E80 Series Maintenance Manual
4 Failure Diagnosis
78
IB-1501273-F
(1) When the 2nd line of the operator message cannot be displayed, only the 1st line is displayed.
The messages are color-coded in the following manner:
The axis name is displayed in messages for each axis. The axis name is displayed as shown below according to the axis
type.
If the same message occurs for different axis types, they will appear as separate messages.
The part system name is also displayed if the message is output for each part system. The part system name set in "#1169
system name" is displayed. The part system name does not appear for the 1-part system.
Display items
Display items
Details
(1)
NC message
This displays the operation alarms, program errors, MCP alarms, servo alarms, sys-
tem alarms, etc.
Up to 10 messages are displayed in order of priority.
(2)
Stop code
This displays the automatic operation status or stop status during automatic operation.
Up to 4 messages are displayed in order of priority.
(3)
Alarm message
Using the PLC programs, this displays messages such as details of machine abnor-
malities. This varies depending on the MTB specifications.
Up to 4 messages are displayed.
(4)
Operator message
Using the PLC programs, this displays operator information messages. This varies de-
pending on the MTB specifications.
Macro alarm messages are also displayed in this field.
Up to 4 messages are displayed.
Message display colors
Message type
Character color
Background color
NC message
Alarm
White
Red
Warning
Black
Yellow
Stop code
Black
Yellow
Alarm message
White
Red
Operator message
Black
Yellow
NC alarm message at the background check
White
Orange
Axis name display
Axis type
Axis name display
Display
example
Remarks
NC axis
Control axis name (Name of axis in
part system)
XYZ
If the same message occurs for each part system,
several NC axes are displayed together.
Spindle
'S' + spindle No.
S1S2
If the same message occurs, several spindles are
displayed together.
PLC axis
'P' + PLC axis No.
P1P2
If the same message occurs, several PLC axes are
displayed together.
Auxiliary axis
'A' + auxiliary axis No.
A1A2
If the same message occurs, several auxiliary axes
are displayed together.
Part system display
Note
Summary of Contents for E80 Series
Page 1: ......
Page 7: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 28: ...1 1 IB 1501273 F System Basic Configuration ...
Page 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Page 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Page 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Page 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Page 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Page 166: ...5 139 IB 1501273 F Troubleshooting ...
Page 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Page 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Page 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Page 212: ......