M800/M80/E80 Series Maintenance Manual
3 Maintenance of the Drive Unit
58
IB-1501273-F
Replacement procedure
Replace the battery with the following procedures.
<Replacement procedure for the cell battery MDS-BAT6V1SET>
(1) Open the battery holder cover located at the front of the drive unit.
(2) Pull out the battery connector connected with the drive unit. Remove the battery.
(3) Install a new battery and connect a cable connector to the connector position where the old battery connector was pulled
out from in step (2).
(4) Cancel the warning 9F by executing an alarm reset (pushing the NC reset button).
CAUTION
1. Replace the batteries with new ones immediately after the battery voltage drop alarm (9F) has been output.
2. Replace the batteries while applying the drive unit’s control power.
1 2 1 2
1
1
2
2
BTI
BTO
BTA
BTB
Connect the battery box with BTI.
Battery connector connection part magnified figure
Battery attaching part
Battery unit
Summary of Contents for E80 Series
Page 1: ......
Page 7: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 28: ...1 1 IB 1501273 F System Basic Configuration ...
Page 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Page 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Page 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Page 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Page 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Page 166: ...5 139 IB 1501273 F Troubleshooting ...
Page 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Page 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Page 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Page 212: ......