Operation and Maintenance
218
Mitel SMB Controller
syd-0657/2.0 – R6.0 – 09.2018
Synchronisation with backup
communication server suc-
cessful
The primary communication server was able
(following one or more previous failed attempts)
to transmit the configuration data to the backup
communication server.
Note:
This event message is generated by the primary
communication server.
Backup communica-
tion server ID, date,
time
critical
(positive,
with
match)
Synchronization on trunk re-
established
A BRI/PRI interface entered in the clock pool
has been successfully re-synchronized with the
system clock.
Port number, date,
time
Serious
(positive,
with
match)
System memory usage below
the critical range again
The memory usage in the file system for a spe-
cific purpose has again fallen below a defined
(
Serious
severity level) or critical (
Critical
sever-
ity level) value.
Purpose (file type ID):
0: File system, 1: Application, 2: Crash-Log,
3: Monitor-Log, 4: Announcement service,
5: Voice mail, 6: Music on hold, 7: Data backup,
8: Hospitality/Accommodation, 9: User folder
File type ID, memory
usage in %, date,
time
Serious /
Critical
(positive,
with
match)
System memory usage over
the critical range
The memory usage in the file system for a spe-
cific purpose has exceeded a defined (
Serious
severity level) or critical (
Critical
severity level)
value.
Purpose (file type ID):
0: File system, 1: Application, 2: Crash-Log,
3: Monitor-Log, 4: Announcement service,
5: Voice mail, 6: Music on hold, 7: Data backup,
8: Hospitality/Accommodation, 9: User folder
File type ID, memory
usage in %, date,
time
Serious /
Critical
(negative,
with
match)
System overload
Network access attempted when all lines are
seized or the system is overloaded.
Route number, user
number, date, time
Normal
(without
match)
System phone in service
again
A system phone on the DSI bus is ready for
operation again.
Card number, port
number, user num-
ber, date, time
critical
(positive,
with
match)
System phone out of service
A system phone on the DSI bus is defective or
was disconnected.
Card number, port
number, user num-
ber, date, time
critical
(negative,
with
match)
Temperature within normal
range again
Following overheating, the temperature inside
the communication server is back in the normal
operating range.
Card number, tem-
perature, date, time
critical
(positive,
with
match)
Temporary activation expires
on
Reminder of the missing, definitive activation
licence following connection set-up with the
communication server.
Expiration date
[DD.MM.YYYY],
date, time
Serious
(without
match)
Event message
Trigger condition
Details
1)
Severity