Operation and Maintenance
209
Mitel SMB Controller
syd-0657/2.0 – R6.0 – 09.2018
Fan failure
(Mitel 470 only)
The fan is jammed or defective or the connection
is no longer making contact.
• Parameter 1 = 0: No more fans in operation.
−>
Risk of overheating: System shut down
after 2 minutes.
−>
Replace both fans.
• Parameter 1 = 1: Only one fan left in opera-
tion.
Parameter 2 = Defective fan number
−>
System still running with only one fan.
−>
Replace defective fan.
Parameter 1,
parameter 2, date,
time
critical
(negative,
with
match)
Fan in operation
(Mitel 415/430 and
Mitel SMBC only)
The fan is back in service again after a failure.
• Parameter = 0: Fan back in service again.
Parameter, date,
time
critical
(positive,
with
match)
Fan in operation
(Mitel 470
only)
The fan is back in service again after a failure.
• Parameter = 0: A fan is back in service again.
• Parameter = 1: Second fan back in service
again.
Parameter, date,
time
critical
(positive,
with
match)
FIAS command buffer full
The command buffer to the PMS interface is full. Date, time
critical
(negative,
with
match)
FIAS interface usable again
The command buffer to the PMS interface is
back below the critical limit.
Date, time
critical
(positive,
with
match)
Inactive radio unit port
Radio unit not responding
Reason: 0: Startup running, 1: Not registered,
2: Various nodes, 3: Port not permitted, 4: Local
power supply, 5: Not connected, 6: Port reset,
7: Startup error, 8: Unknown error
Card number, port
number, radio unit
ID/reason, date, time
Serious
(negative,
with
match)
Incompatible PMS applica-
tion
The external hotel management system (PMS
application) is not suitable for communicating
with the communication server.
PMS SW version,
PMS interface ver-
sion, PMS interface
driver version, date,
time
critical
(negative,
with
match)
Incorrect or no wiring adapter
(Mitel 415/430 and
Mitel SMBC only)
There is no wiring adapter in the wiring adapter
slot or the wiring adapter fitted is unsuitable.
Slot number, date,
time
Critical
(without
match)
Insufficient bandwidth
An user in an AIN is trying to set up a connection
and the bandwidth currently available with the
WAN link is insufficient.
Link ID, WAN link
name, available
bandwidth in Kbit/s,
date, clock
Serious
(without
match)
Event message
Trigger condition
Details
1)
Severity