Installation
95
Mitel SMB Controller
syd-0657/2.0 – R6.0 – 09.2018
• The space on the left and right between the communication server and the panels of
the 19” rack is for heat dissipation and must remain clear.
• With interface cards with more than 8 ports it is advisable to route the cabling via an
fan-out-panel (FOP) (1 height unit).
Fig. 16
Placing two communication servers above each other inside a 19” rack
4. 2. 7. 1
Rack-mounting procedure
Materials required:
• Rack-mounting kit
• Screw set for wall/desktop installation
• Screwdriver
To rack-mount a communication server proceed as follows:
1. Pull off the screw covers on the left and right of the front panel.
2. Secure the mounting plates to the communication server using the M4 screws.
Make sure the front panel and the mounting plate are aligned.