Overload code displays Office 135 / Office 160
The overload code displays on the cordless phones Office 135 and Office 160 can be
activated and deactivated using the following key combination (toggle function):
Long-click key 5 and then long-click key 3 (long = long-click = 2 seconds).
The overload code display is always deactivated after system initialization.
Tab. 98
DECT overload code displays Office 135
6. 5. 3
Other aids
6. 5. 3. 1
System logs
During operation or in the event of a malfunction the communication server stores the
current operating data in the file system in the directory
/home/mivo400/logs
.
You can open, view and back up these log files on any storage device, in WebAdmin in
the
System logs
(
=1w
) view.
6. 5. 3. 2
File system state
In the
File system state
(
=e3
) view you can see the thematically structured file sys-
tem's memory load. In an AIN the file systems for all nodes can be viewed.
Code
Name
Error description
Error handling
05 / 06
IPEI Not Accepted
Cordless phone already registered with
the system under a different number.
• Delete cordless phone registration.
• Try again
10
Authentication failed
Registration error
Try again
51
DL 04 Expiry
Timer (on cordless phone) has expired
Try again
70
Timer Expired
MM timer in system has expired (during
registration)
Try again
44
Failure to set up traffic
bearer
Connection cannot be set up as too
many cordless phones are phoning
within the same range
• Try again
• If still unsuccessful after several
attempts, restart cordless phone
and try again.
45
No Quiet Channel
No channel available, same as code 44 Same measures as for code 44
80
Reject Location Area.
Not allowed. Mis-used
to indicate wrong
"design" version.
Wrong mode during logon.
Logon to the system < I5
• Office 135: Longclick "Home"
Logon to the system > I5: