Operation and Maintenance
180
Mitel SMB Controller
syd-0657/2.0 – R6.0 – 09.2018
6. 1. 1. 1
System software
When we talk about the system software we have to distinguish between the SMB
Controller system software (based on Linux) and the MiVoice Office 400 application
software, running in this Linux environment. Both software packages are stored in
compressed form in the Flash memory.
The RAM components comprise the main memory for program data. When the com-
munication server starts up, the software on the Flash memory is decompressed,
loaded into the main memory and started.
6. 1. 1. 2
File system
When we talk about the file system, we have to distinguish between the SMB Control-
ler file system (based on Linux) and the MiVoice Office 400 file system:
SMB Controller file system
The SMB Controller file system comprises the system software, the emergency system
software and the boot software. The SMB Controller Manager (including the help files)
is part of the system software and in reduced form part of the emergency system soft-
ware.
Usually there is no need to access the SMB Controller file system, as all needed func-
tions are available in the SMB Controller Manager. For special cases you can access
the SMB Controller file system with a SSH session.
MiVoice Office 400 file system
The file system of the MiVoice Office 400 communication server comprises the MiVoice
Office 400 application software, the software for system phones, the system and termi-
nal configuration data, the audio data, system logs, data for WebAdmin, etc. With
WebAdmin you have access to the file system via the menu item
File management
.
You can see the file system memory load and you can load audio data, languages for
the user interface and online help, language files for Mitel 6800/6900 SIP-series
phones as well as an external numbering plan for SIP connection. Moreover, with the
file browser you have the possibility to view, upload, replace or delete folders and files
in the file system. (see also "File management", page 172).
Functions for backing up and restoring MiVoice Office 400 configuration data and au-
dio data are available in the WebAdmin
Maintenance
/
Data backup
(
=um
) view (see
also "Data backup", page 175).
Usually there is no need to access the MiVoice Office 400 file system directly as all
needed functions are available in WebAdmin. For special cases you can access the
MiVoice Office 400 file system with a SSH session via the folder
/home/mivo400
.