FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T-70
(2)
Only the Power Supply Cooling Fan rotates.
(3)
Control panel indicators do not light.
Relevant Electrical Parts
PIC Board (PWB-PIC)
DC Power Supply 1 (PU1)
DC Power Supply 2 (PU2)
Step
Check Item
WIRING
DIAGRAM
(Location)
Result
Action
1
Is DC3.3 V being output from PJ9PU1-1
on PU1?
29-F
NO
Change PU1.
2
Is DC5 V being output from CN2PU2-2
on PU2?
31-F
NO
Change PU2.
3
Is DC3.3 V being input to PJ1PIC-1 on
PWB-PIC and DC5 V to PJ1PIC-3?
32-C
YES
Change PWB-PIC.
NO
Check the wiring.
Relevant Electrical Parts
Image Processing Board (PWB-C)
Control Panel (UN201)
DC Power Supply 3 (PU201)
Step
Check Item
WIRING
DIAGRAM
(Location)
Result
Action
1
Is the I/F cable between the IR and
engine connected properly?
—
NO
Reconnect or
change the I/F
cable.
2
Is a power voltage being applied across
CN3PU201-1 and 2 on PU201?
22-H
NO
Check the wiring
from the wall outlet
to CN3PU201-1/2.
3
Is the fuse (F1) on PU201 conducting?
—
NO
Change PU201.
4
Is DC5.1 V being output from
CN2PU201-1 on PU201 and DC24 V
from CN2PU201-3?
22-H
NO
Change PU201.
5
Is PJ12C on PWB-C securely con-
nected?
26-E
NO
Reconnect.
6
Is CN12 on UN201 securely con-
nected?
24-F
NO
Reconnect.
YES
Change UN201.
Change PWB-C.
Summary of Contents for CF2002
Page 1: ...The essentials of imaging www minoltaeurope com Service Manual CF2002 CF3102 ...
Page 2: ......
Page 21: ...FrameMaker Ver 5 5E PC CF2002 CF3102 GENERAL 02 06 26 GENERAL 14413 ...
Page 30: ...FrameMaker Ver 5 5E PC CF2002 CF3102 MAINTENANCE 02 06 26 MAINTENANCE 14413 ...
Page 178: ...FrameMaker Ver 5 5E PC CF2002 CF3102 TROUBLESHOOTING 02 06 26 TROUBLESHOOTING 14413 ...