(13) IR System: abnormal image
<Typical Faulty Images>
<Troubleshooting Procedure>
Section
Step
Check Item
Result
Action
Cable
connecting
IR and printer
1
Connector is connected prop-
erly with no pins bent.
NO
Reconnect.
Connection cable
between control-
ler
I/F board and
Image
Control Board
(PWB-F)
2
Connector is connected prop-
erly with no pins bent.
NO
Reconnect.
Image
Processing
Board
(PWB-C)
3
Connectors on the Image
Processing Board are con-
nected properly.
NO
Reconnect.
Image
Processing Inter-
face Board
(PWB-B)
4
Connectors on the Image
Processing Board are con-
nected properly.
NO
Reconnect.
Image Control
Board
(PWB-F)
5
Data on previous page is
mixed with data on current
page.
NO
Reinstall expanded mem-
ory.
Test Print
(Tech.Rep.Mode)
6
The problem is eliminated as
checked with the image on a
test pattern produced.
NO
Change interface connec-
tion cable.
Image
Processing
Board
(PWB-C)
7
The problem is eliminated
after the interface connection
cable has been changed.
NO
Change Image Process-
ing Board.
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE
4011T053AA
CF
ABCDE
ABCDE
ABCDE
Data on previous page
Data on current page
4011T063AA
4004T010AB
Summary of Contents for CF2002
Page 1: ...The essentials of imaging www minoltaeurope com Service Manual CF2002 CF3102 ...
Page 2: ......
Page 21: ...FrameMaker Ver 5 5E PC CF2002 CF3102 GENERAL 02 06 26 GENERAL 14413 ...
Page 30: ...FrameMaker Ver 5 5E PC CF2002 CF3102 MAINTENANCE 02 06 26 MAINTENANCE 14413 ...
Page 178: ...FrameMaker Ver 5 5E PC CF2002 CF3102 TROUBLESHOOTING 02 06 26 TROUBLESHOOTING 14413 ...