FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T-76
(2)
IR System: white lines in CD, white bands in CD, colored lines in CD, and col-
ored bands in CD
<Typical Faulty Images>
<Troubleshooting Procedure>
Section
Step
Check Item
Result
Action
Original
1
Original is damaged or dirty.
YES
Change original.
Original Cover
2
Original Pad is dirty.
YES
Clean.
Original Glass
3
Original Glass is dirty.
YES
Wipe the surface clean
with a soft cloth.
Machine Adjust
→
IR Area
→
Top Image
(Tech. Rep. Mode)
4
The adjustment value for Top
Image falls within the speci-
fied range.
Readjust.
5
The problem has been elimi-
nated through the checks of
steps up to 4.
NO
Change Scanner Assy.
Change CCD Unit.
White lines in CD
White bands in CD
Color bands in CD
Color lines in CD
4011T016AA
4011T021AA
4011T018AA
4011T022AA