FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T-86
(12) IR System: blank copy, black copy
<Typical Faulty Images>
<Troubleshooting Procedure>
Section
Step
Check Item
Result
Action
Cable
connecting IR
and printer
1
Connector is connected
properly with no pins bent.
NO
Reconnect.
Image
Processing
Board
(PWB-C)
2
Connectors on the Image
Processing Board are con-
nected properly.
NO
Reconnect.
CCD Unit
3
Connectors of the CCD Unit
are connected properly.
NO
Reconnect.
Test Print
(Tech.Rep.Mode)
4
The problem is eliminated
as checked with the image
on a test pattern produced.
NO
Change I/F connection
cable.
Image
Processing
Board
(PWB-C)
5
The problem is eliminated
after the I/F connection
cable has been changed.
NO
Change Image Processing
Board.
Blank copy
Black copy
4011T036AA
4011T035AA