(24) C0200: Cyan PC Drum Charge Corona malfunction
(25) C0202: Magenta PC Drum Charge Corona malfunction
(26) C0204: Yellow PC Drum Charge Corona malfunction
(27) C0206: Black PC Drum Charge Corona malfunction
(28) C0208: PC Drum Charge Corona malfunction
<Detection Timing>
<Action>
Malfunction Code
Description
C0200
The SCD signal is detected for a continuous 0.7-sec. period when
the Cyan PC Drum Charge Corona is automatically energized as
the malfunction is reset after C0208 (PC Drum Charge Corona
malfunction) has been detected.
C0202
The SCD signal is detected for a continuous 0.7-sec. period when
the Magenta PC Drum Charge Corona is automatically energized
as the malfunction is reset after C0208 (PC Drum Charge Corona
malfunction) has been detected.
C0204
The SCD signal is detected for a continuous 0.7-sec. period when
the Yellow PC Drum Charge Corona is automatically energized as
the malfunction is reset after C0208 (PC Drum Charge Corona
malfunction) has been detected.
C0206
The SCD signal is detected for a continuous 0.7-sec. period when
the Black PC Drum Charge Corona is automatically energized as
the malfunction is reset after C0208 (PC Drum Charge Corona
malfunction) has been detected.
C0208
The SCD signal is detected for a continuous 0.7-sec. period while
the PC Drum Charge Corona is being energized.
Relevant Electrical Parts
IU C/M/Y/Bk
High Voltage Unit (PC Drum CH.) HV1
IO Board (PWB-IO)
Step
Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Check the IU contact and cor-
rect or clean as necessary.
—
—
—
2
Check the HV1 contact and
correct or clean as necessary.
—
—
—
3
Change IU.
—
—
—
4
Change HV1.
—
—
—
5
Change PWB-IO
—
—
—
Summary of Contents for CF2002
Page 1: ...The essentials of imaging www minoltaeurope com Service Manual CF2002 CF3102 ...
Page 2: ......
Page 21: ...FrameMaker Ver 5 5E PC CF2002 CF3102 GENERAL 02 06 26 GENERAL 14413 ...
Page 30: ...FrameMaker Ver 5 5E PC CF2002 CF3102 MAINTENANCE 02 06 26 MAINTENANCE 14413 ...
Page 178: ...FrameMaker Ver 5 5E PC CF2002 CF3102 TROUBLESHOOTING 02 06 26 TROUBLESHOOTING 14413 ...