FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T-31
3-1.
Warning Detection Timing and Troubleshooting Procedure
• If an image stabilization or IR-related fault occurs, the corresponding warning code
appears.
(1)
P-5: AIDC Sensor (Front) failure
(2)
P-28 AIDC Sensor (Back) failure
<Detection Timing>
<Action>
Warning Code
Description
P-5
• The output from the photoreceiver of the AIDC Sensor that takes a
reading of a point of a bare surface on the Transfer Belt is 4.5 V or
more during an adjustment of the AIDC Sensor.
• The output from the photoreceiver of the AIDC Sensor that takes a
reading of a point in a toner pattern on the Transfer Belt is 1.0 V or
less after the adjustment has been completed.
P-28
Relevant Electrical Parts
AIDC Sensor 1 (UN20)
AIDC Sensor 2 (UN21)
IO Board (PWB-IO)
Image Transfer Belt Unit
Step
Action
1
Wipe clean the surface of the Transfer Belt with a soft cloth, if it is dirty.
2
Change the Image Transfer Belt Unit if the Transfer Belt is damaged.
3
Reinstall or reconnect UN20 or UN21 if it is installed or connected improperly.
4
Clean UN20 or UN21 if it is dirty.
5
Open and close the Left Door, run an image stabilization sequence, and
select “State Confirm” -> “Level History 1” to check the AIDC value.
If the value is 1.0 V or less, change UN20 or UN21.
6
Change PWB-IO.
Summary of Contents for CF2002
Page 1: ...The essentials of imaging www minoltaeurope com Service Manual CF2002 CF3102 ...
Page 2: ......
Page 21: ...FrameMaker Ver 5 5E PC CF2002 CF3102 GENERAL 02 06 26 GENERAL 14413 ...
Page 30: ...FrameMaker Ver 5 5E PC CF2002 CF3102 MAINTENANCE 02 06 26 MAINTENANCE 14413 ...
Page 178: ...FrameMaker Ver 5 5E PC CF2002 CF3102 TROUBLESHOOTING 02 06 26 TROUBLESHOOTING 14413 ...