FrameMaker Ver5.5E(PC) CF3102/CF2002 DIS/REASSEMBLY, ADJUSTMENT
02.06.010
D-10
(2)
Removal of the Image Processing Board and Image Processing Interface Board
1. Remove the Original Glass.
2. Remove 14 screws and optical cover.
4025E006AB
3. Unplug the connectors and remove the cord
clamps of the Original Size Detecting Sensors.
4. Remove 12 screws and the Image Processing
Board lid.
4025D010AC
5. Remove the Image Processing Interface Board
cable.
4025D011AB
6. Unplug all connectors of the Image Processing
Board.
4025D012AA
7. Remove the IR hookup cable.
NOTES
• Be sure to hold onto the connector when removing
or installing the cable. NEVER pull on the cable.
• At reinstallation, make sure that the Connector is
not Tilted.
4004D010AA
Summary of Contents for CF2002