FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T-83
(9)
IR System: distorted image
<Typical Faulty Image>
<Troubleshooting Procedure>
Section
Step
Check Item
Result
Action
Installation
1
IR is installed on a level sur-
face if mounted without any
rack.
NO
Reinstall.
Rack is installed on a level sur-
face.
NO
Reinstall.
The Rack is tilted with a lot of
play.
YES
Adjust rack leg height.
2nd/3rd
Mirrors Car-
riage
2
Scanner Assy is not properly
aligned with 2nd/3rd Mirrors
Carriage.
YES
Readjust with the Scanner/
Mirrors Carriage Positioning
Jigs.
Scanner
Motor
3
Scanner Motor turns smoothly.
NO
Change belt.
Change Scanner Motor.
4
The problem has been elimi-
nated through the checks of
steps up to 3.
NO
Change Scanner Assy.
Change CCD Unit.
4011T045AA
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE