FrameMaker Ver5.5E(PC) CF3102/CF2002 MAINTENANCE
02.06.05
E-15
(17) Replacing Ozone Filter
(18) Cleaning of the Comb Electrode
1. Holding onto the hook, remove the Ozone Filter.
2. Remove the Paper Dust Remover. [See (7)
Replacement of the Paper Dust Remover.]
3. To reinstall, reverse the order of removal.
4. Select “Tech. Rep. Mode”
→
“Counter”
→
”Life”
and clear the count of “Paper Powder Filter/
Ozone Filter.”
4025E011AA
1. Open the Front Door.
2. Clean the Comb Electrode by moving the Comb
Electrode Cleaning Lever In and Out several
times.
NOTE
• Move the Comb Electrode Cleaning Lever slowly
forward and backward until it stops.
4025E012AA