FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T-82
(8)
IR System: skewed image
<Typical Faulty Image>
<Troubleshooting Procedure>
Section
Step
Check Item
Result
Action
Original
1
Original is skew.
YES
Reposition original.
Original
Glass
2
Original Glass is in positive
contact with the flat spring
without being tilt.
NO
Reinstall the glass. Check the
original loading position.
2nd/3rd
Mirrors Car-
riage
3
Scanner Assy is not properly
aligned with 2nd/3rd Mirrors
Carriage.
YES
Readjust with the Scanner/
Mirrors Carriage Positioning
Jigs.
4
The problem has been elimi-
nated through the checks of
steps up to 3.
NO
Change Scanner Assy.
Change CCD Unit.
C F
4011T048AA