FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T-54
(47) C0F3A: Cyan ATDC Sensor adjustment failure
(48) C0F3B: Magenta ATDC Sensor adjustment failure
(49) C0F3C: Yellow ATDC Sensor adjustment failure
(50) C0F3D: Black ATDC Sensor adjustment failure
<Detection Timing>
<Action>
C0F3A, C0F3B, C0F3C
Malfunction Code
Description
C0F3A
Cyan ATDC Sensor automatic adjustment does not function prop-
erly, failing to adjust to an appropriate value.
C0F3B
Magenta ATDC Sensor automatic adjustment does not function
properly, failing to adjust to an appropriate value.
C0F3C
Yellow ATDC Sensor automatic adjustment does not function prop-
erly, failing to adjust to an appropriate value.
C0F3D
Black ATDC Sensor automatic adjustment does not function prop-
erly, failing to adjust to an appropriate value.
Relevant Electrical Parts
ATDC Sensor C (PWB-N3)
ATDC Sensor M (PWB-N2)
ATDC Sensor Y (PWB-N1)
Toner Replenishing Motor C/Bk (M9)
Toner Replenishing Motor Y/M (M10)
IO Board (PWB-IO)
PIC Board (PWB-PIC)
IU C/M/Y/Bk
Step
Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Clean the ATDC Sensor win-
dow on the underside of the IU
if dirty.
—
—
—
2
Clean the ATDC Sensor LED if
dirty.
—
—
—
3
Correct the contact and/or wir-
ing of the ATDC Sensor if
faulty.
—
—
—
4
Reinstall IU C/M/Y.
—
—
—
5
M9, M10 operation check
T-3
PWB-IO PJ13IO-10 to 13
(Pulse Output): M9
PWB-IO PJ13IO-6 to 9
(Pulse Output): M10
10-A
6
Change IU C/M/Y.
—
—
—
7
Change PWB-IO.
—
—
—
8
Change PWB-PIC
—
—
—
Summary of Contents for CF2002
Page 1: ...The essentials of imaging www minoltaeurope com Service Manual CF2002 CF3102 ...
Page 2: ......
Page 21: ...FrameMaker Ver 5 5E PC CF2002 CF3102 GENERAL 02 06 26 GENERAL 14413 ...
Page 30: ...FrameMaker Ver 5 5E PC CF2002 CF3102 MAINTENANCE 02 06 26 MAINTENANCE 14413 ...
Page 178: ...FrameMaker Ver 5 5E PC CF2002 CF3102 TROUBLESHOOTING 02 06 26 TROUBLESHOOTING 14413 ...