(89) C3700: IR Power Supply Cooling Fan Motor turning at abnormal timing
(90) C3710: IR Drive Board Cooling Fan Motor turning at abnormal timing
<Detection Timing>
<Action>
C3700
C3710
(91) C3FFF: ROM contents fault detected upon start
<Detection Timing>
<Action>
Malfunction Code
Description
C3700
A Lock signal is detected ten consecutive times when it is moni-
tored at 0.01-sec. intervals during a period of time 2 sec. after the
output of a Fan Motor ON signal has been started.
C3710
Relevant Electrical Parts
IR Power Supply Cooling Fan Motor (M202)
IR Drive Board Cooling Fan Motor (M203)
Image Processing Board (PWB-C)
Step
Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
M202 operation check
T-3
PWB-C PJ8C-18B(LOCK)
PWB-C PJ8C-17B(REM)
19-G
2
Change PWB-C.
—
—
—
Step
Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
M203 operation check
T-3
PWB-C PJ8C-15B(LOCK)
PWB-C PJ8C-14B(REM)
19-H
2
Change PWB-C.
—
—
—
Malfunction Code
Description
C3FFF
A fault is detected in the contents of ROM of MSC, IR, and PRT
when the copier is started.
Step
Action
Ref.
Page
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Check the ROM version.
—
—
—
2
Rewrite firmware using the
memory card.
—
—
—
Summary of Contents for CF2002
Page 1: ...The essentials of imaging www minoltaeurope com Service Manual CF2002 CF3102 ...
Page 2: ......
Page 21: ...FrameMaker Ver 5 5E PC CF2002 CF3102 GENERAL 02 06 26 GENERAL 14413 ...
Page 30: ...FrameMaker Ver 5 5E PC CF2002 CF3102 MAINTENANCE 02 06 26 MAINTENANCE 14413 ...
Page 178: ...FrameMaker Ver 5 5E PC CF2002 CF3102 TROUBLESHOOTING 02 06 26 TROUBLESHOOTING 14413 ...